1979Canadian Journal of ChemistryRequires access

Isopotential points in the electrosorption of selenite, selenate, selenide, and tellurite at the platinum rotating disc electrode

Hélio C. Chagas

Open publisher page 8 citations

Abstract

Electrosorption at the platinum rotating disc electrode in sulfuric acid solutions of selenite, selenate, selenide, and tellurite gives rise to isopotential points in the potential range where oxidation of platinum occurs. The data are analyzed with the framework of the model put forward by Untereker and Bruckenstein. Since similar behavior is observed for the selenite, selenate, and selenide systems, it is tentatively inferred that a common electrosorbed species, possibly selenium itself, may be involved in these systems.

About this research paper

What this paper is about

Electrosorption at the platinum rotating disc electrode in sulfuric acid solutions of selenite, selenate, selenide, and tellurite gives rise to isopotential points in the potential range where oxidation of platinum occurs. The data are analyzed with the framework of the model put forward by Untereker and Bruckenstein. Since similar behavior is observed for the selenite, selenate, and selenide systems, it is tentatively inferred that a common electrosorbed species, possibly selenium itself, may be involved in these systems.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electrosorption at the platinum rotating disc electrode in sulfuric acid solutions of selenite, selenate, selenide, and tellurite gives rise to isopotential points in the potential range where oxidation of platinum occurs. The data are analyzed with the framework of the model put forward by Untereker and Bruckenstein. Since similar behavior is observed for the selenite, selenate, and selenide systems, it is tentatively inferred that a common electrosorbed species, possibly selenium itself, may be involved in these systems.

Key concepts: Selenate, Selenium, Selenide, Chemistry, Platinum, Electrode, Inorganic chemistry, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Isopotential points in the electrosorption of selenite, selenate, selenide, and tellurite at the platinum rotating disc electrode — Research Paper | ScholarLens