1996•International Journal of Energy ResearchRequires access

Strategies to raise the off-design efficiency of chiller machines

Asfaw Beyene, Preston Lowrey

Open publisher page 6 citations

Abstract

Most HVAC systems in large buildings are equipped with centrifugal chillers which are typically designed for maximum efficiency at 70% at 80% of their full-load. But, below about 30% full-load, their part-load efficiency starts to deteriorate rapidly (increasing kilowatts per ton). For older centrifugal chillers, this rapid drop may start at even higher part-load, rendering their operation at low part-load undesirable. In many cases chillers are over-sized, forcing operation below 50% of the full-load most of the time. Furthermore, the field performance of most chiller machines is genearlly not documented, and there is no tradition of recording chiller performance history. There is growing incentive-driven interest in chiller monitoring. But, field visits, discussions with HVAC engineers and opinions from manufacturers have proven that virtually no chiller systems are currently monitored for kilowatts per ton. Only recently has field data gathering been initiated, and part-load performance of chillers in the field started drawing serious attention. The problem, however, still remains poorly disclosed to the end-user. As a result, chiller machines actually operate at much lower efficiency than the design values. There are opportunities for profoundly improving their field performance. Part-load operation is particularly poor for sites with single centrifugal chillers. This research is an appraisal of strategies for improving the part-load performance of chiller systems. A review of simulation results and field data indicate that chiller machines operate at higher kilowatts per ton than allowed for by current technology. Energy consumption of various chiller types and configurations for a generic building indicate that there are possibilities for lowering chiller energy consumption, and these opportunities can be harvested with simple measures.

About this research paper

What this paper is about

Most HVAC systems in large buildings are equipped with centrifugal chillers which are typically designed for maximum efficiency at 70% at 80% of their full-load. But, below about 30% full-load, their part-load efficiency starts to deteriorate rapidly (increasing kilowatts per ton). For older centrifugal chillers, this rapid drop may start at even higher part-load, rendering their operation at low part-load undesirable. In many cases chillers are over-sized, forcing operation below 50% of the full-load most of the time. Furthermore, the field performance of most chiller machines is genearlly not documented, and there is no tradition of recording chiller performance history. There is growing incentive-driven interest in chiller monitoring. But, field visits, discussions with HVAC engineers and opinions from manufacturers have proven that virtually no chiller systems are currently monitored for kilowatts per ton. Only recently has field data gathering been initiated, and part-load performance of chillers in the field started drawing serious attention. The problem, however, still remains poorly disclosed to the end-user. As a result, chiller machines actually operate at much lower efficiency than the design values. There are opportunities for profoundly improving their field performance. Part-load operation is particularly poor for sites with single centrifugal chillers. This research is an appraisal of strategies for improving the part-load performance of chiller systems. A review of simulation results and field data indicate that chiller machines operate at higher kilowatts per ton than allowed for by current technology. Energy consumption of various chiller types and configurations for a generic building indicate that there are possibilities for lowering chiller energy consumption, and these opportunities can be harvested with simple measures.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Most HVAC systems in large buildings are equipped with centrifugal chillers which are typically designed for maximum efficiency at 70% at 80% of their full-load. But, below about 30% full-load, their part-load efficiency starts to deteriorate rapidly (increasing kilowatts per ton). For older centrifugal chillers, this rapid drop may start at even higher part-load, rendering their operation at low part-load undesirable. In many cases chillers are over-sized, forcing operation below 50% of the full-load most of the time. Furthermore, the field performance of most chiller machines is genearlly not documented, and there is no tradition of recording chiller performance history. There is growing incentive-driven interest in chiller monitoring. But, field visits, discussions with HVAC engineers and opinions from manufacturers have proven that virtually no chiller systems are currently monitored for kilowatts per ton. Only recently has field data gathering been initiated, and part-load performance of chillers in the field started drawing serious attention. The problem, however, still remains poorly disclosed to the end-user. As a result, chiller machines actually operate at much lower efficiency than the design values. There are opportunities for profoundly improving their field performance. Part-load operation is particularly poor for sites with single centrifugal chillers. This research is an appraisal of strategies for improving the part-load performance of chiller systems. A review of simulation results and field data indicate that chiller machines operate at higher kilowatts per ton than allowed for by current technology. Energy consumption of various chiller types and configurations for a generic building indicate that there are possibilities for lowering chiller energy consumption, and these opportunities can be harvested with simple measures.

Key concepts: Chiller, Chiller boiler system, Process engineering, Computer science, Environmental science, Water chiller, Engineering, Mechanical engineering