2006•Acta OrthopaedicaOpen access

Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: I. Preliminary investigations—52 patients followed for 3 years

Lars V. Carlsson, Björn E.J. Albrektsson, Björn Albrektsson, Tomas O. Albrektsson, C M Jacobsson, Warren Macdonald, Lars Regnér, Tord Röstlund, Lars R.A. Weidenhielm

Open full text 23 citations

Abstract

BACKGROUND: We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum. PATIENTS AND METHODS: A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress. RESULTS: No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group. INTERPRETATION: Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: "osseointegration".

Open-access reader

About this research paper

What this paper is about

BACKGROUND: We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum. PATIENTS AND METHODS: A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress. RESULTS: No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group. INTERPRETATION: Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: "osseointegration".

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum. PATIENTS AND METHODS: A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress. RESULTS: No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group. INTERPRETATION: Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: "osseointegration".

Key concepts: Osseointegration, Medicine, Harris Hip Score, Dentistry, Implant, Arthroplasty, Acetabulum, Osteolysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: I. Preliminary investigations—52 patients followed for 3 years — Research Paper | ScholarLens