2010British journal of surgeryRequires access

Intraoperative ultrasonographic detection of communicating veins between adjacent hepatic veins during hepatectomy for tumours at the hepatocaval confluence

G Torzilli, Mattia Garancini, Matteo Donadon, Matteo Cimino, Fabio Procopio, Marco Montorsi

Open publisher page 75 citations

Abstract

BACKGROUND: The presence of communicating veins between adjacent hepatic veins may allow parenchyma-sparing hepatectomy. Taking advantage of improvements in ultrasound technology, such as e-flow modality, a study of the presence of communicating veins was conducted in patients with hepatic tumours at the caval confluence. METHODS: Consecutive patients undergoing surgery between October 2007 and December 2009 for hepatic tumours in contact with or invading a hepatic vein at its caval confluence were included. Communicating vein mapping by means of e-flow intraoperative ultrasonography (EF-IOUS) was carried out. RESULTS: A total of 20 patients were enrolled. Communicating veins between adjacent hepatic veins or with the inferior vena cava were detected in 16 patients. The median number of communicating veins was 1 (range 0-5). The total number of lesions removed was 126 (range 1-46). In 11 of 12 patients requiring resection of a hepatic vein, communicating veins enabled a parenchyma-sparing procedure to be performed. No patient had a formal major hepatectomy. There was no postoperative mortality or major morbidity. CONCLUSION: EF-IOUS estimation of the frequency of communicating veins between adjacent hepatic veins suggests that such veins are common. This may facilitate parenchyma-sparing procedures in patients with hepatic tumours encroaching on major hepatic veins.

About this research paper

What this paper is about

BACKGROUND: The presence of communicating veins between adjacent hepatic veins may allow parenchyma-sparing hepatectomy. Taking advantage of improvements in ultrasound technology, such as e-flow modality, a study of the presence of communicating veins was conducted in patients with hepatic tumours at the caval confluence. METHODS: Consecutive patients undergoing surgery between October 2007 and December 2009 for hepatic tumours in contact with or invading a hepatic vein at its caval confluence were included. Communicating vein mapping by means of e-flow intraoperative ultrasonography (EF-IOUS) was carried out. RESULTS: A total of 20 patients were enrolled. Communicating veins between adjacent hepatic veins or with the inferior vena cava were detected in 16 patients. The median number of communicating veins was 1 (range 0-5). The total number of lesions removed was 126 (range 1-46). In 11 of 12 patients requiring resection of a hepatic vein, communicating veins enabled a parenchyma-sparing procedure to be performed. No patient had a formal major hepatectomy. There was no postoperative mortality or major morbidity. CONCLUSION: EF-IOUS estimation of the frequency of communicating veins between adjacent hepatic veins suggests that such veins are common. This may facilitate parenchyma-sparing procedures in patients with hepatic tumours encroaching on major hepatic veins.

Why it matters

OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The presence of communicating veins between adjacent hepatic veins may allow parenchyma-sparing hepatectomy. Taking advantage of improvements in ultrasound technology, such as e-flow modality, a study of the presence of communicating veins was conducted in patients with hepatic tumours at the caval confluence. METHODS: Consecutive patients undergoing surgery between October 2007 and December 2009 for hepatic tumours in contact with or invading a hepatic vein at its caval confluence were included. Communicating vein mapping by means of e-flow intraoperative ultrasonography (EF-IOUS) was carried out. RESULTS: A total of 20 patients were enrolled. Communicating veins between adjacent hepatic veins or with the inferior vena cava were detected in 16 patients. The median number of communicating veins was 1 (range 0-5). The total number of lesions removed was 126 (range 1-46). In 11 of 12 patients requiring resection of a hepatic vein, communicating veins enabled a parenchyma-sparing procedure to be performed. No patient had a formal major hepatectomy. There was no postoperative mortality or major morbidity. CONCLUSION: EF-IOUS estimation of the frequency of communicating veins between adjacent hepatic veins suggests that such veins are common. This may facilitate parenchyma-sparing procedures in patients with hepatic tumours encroaching on major hepatic veins.

Key concepts: Medicine, Hepatic veins, Hepatectomy, Vein, Parenchyma, Radiology, Inferior vena cava, Liver parenchyma

Related papers

Back to paper searchBrowse research topicsOriginal source
Intraoperative ultrasonographic detection of communicating veins between adjacent hepatic veins during hepatectomy for tumours at the hepatocaval confluence — Research Paper | ScholarLens