2010Journal of GlaucomaRequires access

Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma

Satoshi Mori, Masanori Hangai, Atsushi Sakamoto, Nagahisa Yoshimura

Open publisher page 96 citations

Abstract

PURPOSE: To determine the glaucoma diagnostic power of measuring the volume of the ganglion cell complex (GCC; 3 innermost retinal layers) using spectral-domain optical coherence tomography (SD-OCT). PATIENTS AND METHODS: Fifty eyes with open-angle glaucoma and 35 normal partipants were included for this study. SD-OCT (RTVue-100), and time-domain (TD)-OCT were used to measure total retinal, GCC (SD-OCT only), and circumpapillary retinal nerve fiber layer (cpRNFL) thicknesses in 50 eyes with open-angle glaucoma and in 35 without glaucoma. RESULTS: Total retinal and GCC volumes in a macular area correlated with visual field mean deviation (GCC: r=0.580, P<0.001; total: r=0.458, P<0.001). The area under the receiver operating characteristic curve (AROC) was greater for macular GCC volume (0.922) than for macular total retinal volume, as measured by SD-OCT (0.857; P=0.020) or TD-OCT (0.841; P=0.025). GCC AROCs were smaller than cpRNFL AROCs determined using SD-OCT (0.971; P=0.110) or TD-OCT (0.970; P=0.122), but not in a statistically significant manner. AROC for the GCC was greatest in the inferior macula. Interclass correlation coefficient values were comparable for GCC and total retinal volumes. CONCLUSION: Selective measurement of the GCC layer by SD-OCT improves diagnostic performance of the macular structural analysis for glaucoma diagnosis.

About this research paper

What this paper is about

PURPOSE: To determine the glaucoma diagnostic power of measuring the volume of the ganglion cell complex (GCC; 3 innermost retinal layers) using spectral-domain optical coherence tomography (SD-OCT). PATIENTS AND METHODS: Fifty eyes with open-angle glaucoma and 35 normal partipants were included for this study. SD-OCT (RTVue-100), and time-domain (TD)-OCT were used to measure total retinal, GCC (SD-OCT only), and circumpapillary retinal nerve fiber layer (cpRNFL) thicknesses in 50 eyes with open-angle glaucoma and in 35 without glaucoma. RESULTS: Total retinal and GCC volumes in a macular area correlated with visual field mean deviation (GCC: r=0.580, P<0.001; total: r=0.458, P<0.001). The area under the receiver operating characteristic curve (AROC) was greater for macular GCC volume (0.922) than for macular total retinal volume, as measured by SD-OCT (0.857; P=0.020) or TD-OCT (0.841; P=0.025). GCC AROCs were smaller than cpRNFL AROCs determined using SD-OCT (0.971; P=0.110) or TD-OCT (0.970; P=0.122), but not in a statistically significant manner. AROC for the GCC was greatest in the inferior macula. Interclass correlation coefficient values were comparable for GCC and total retinal volumes. CONCLUSION: Selective measurement of the GCC layer by SD-OCT improves diagnostic performance of the macular structural analysis for glaucoma diagnosis.

Why it matters

OpenAlex reports 96 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To determine the glaucoma diagnostic power of measuring the volume of the ganglion cell complex (GCC; 3 innermost retinal layers) using spectral-domain optical coherence tomography (SD-OCT). PATIENTS AND METHODS: Fifty eyes with open-angle glaucoma and 35 normal partipants were included for this study. SD-OCT (RTVue-100), and time-domain (TD)-OCT were used to measure total retinal, GCC (SD-OCT only), and circumpapillary retinal nerve fiber layer (cpRNFL) thicknesses in 50 eyes with open-angle glaucoma and in 35 without glaucoma. RESULTS: Total retinal and GCC volumes in a macular area correlated with visual field mean deviation (GCC: r=0.580, P<0.001; total: r=0.458, P<0.001). The area under the receiver operating characteristic curve (AROC) was greater for macular GCC volume (0.922) than for macular total retinal volume, as measured by SD-OCT (0.857; P=0.020) or TD-OCT (0.841; P=0.025). GCC AROCs were smaller than cpRNFL AROCs determined using SD-OCT (0.971; P=0.110) or TD-OCT (0.970; P=0.122), but not in a statistically significant manner. AROC for the GCC was greatest in the inferior macula. Interclass correlation coefficient values were comparable for GCC and total retinal volumes. CONCLUSION: Selective measurement of the GCC layer by SD-OCT improves diagnostic performance of the macular structural analysis for glaucoma diagnosis.

Key concepts: Glaucoma, Optical coherence tomography, Ophthalmology, Nerve fiber layer, Medicine, Retinal, Open angle glaucoma, Receiver operating characteristic

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma — Research Paper | ScholarLens