Characterization of branched polymers by size exclusion chromatography coupled with multiangle light scattering detector. I. Size exclusion chromatography elution behavior of branched polymers
Štěpán Podzimek, T. Vlček, Christoph Johann
Abstract
Štěpán Podzimek, T. Vlček, Christoph Johann
Abstract
Abstract The elution behavior of branched macromolecules during their separation by size exclusion chromatography (SEC) was studied. The elution behavior of branched polymers was investigated using samples of randomly branched polystyrene and star branched poly(benzyl methacrylate) of different levels of branching by means of a SEC chromatograph coupled with a multiangle light scattering detector. Abnormal SEC elution behavior was found to be typical for highly branched polymers. After a normal elution at small elution volumes the molar mass and root mean square radius of the eluting molecules increased with increasing elution volume. Several SEC experiments were carried out to find explanation for this effect and SEC separation was compared with the separation by thermal field flow fractionation. © 2001 John Wiley & Sons, Inc. J Appl Polym Sci 81: 1588–1594, 2001
OpenAlex reports 169 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract The elution behavior of branched macromolecules during their separation by size exclusion chromatography (SEC) was studied. The elution behavior of branched polymers was investigated using samples of randomly branched polystyrene and star branched poly(benzyl methacrylate) of different levels of branching by means of a SEC chromatograph coupled with a multiangle light scattering detector. Abnormal SEC elution behavior was found to be typical for highly branched polymers. After a normal elution at small elution volumes the molar mass and root mean square radius of the eluting molecules increased with increasing elution volume. Several SEC experiments were carried out to find explanation for this effect and SEC separation was compared with the separation by thermal field flow fractionation. © 2001 John Wiley & Sons, Inc. J Appl Polym Sci 81: 1588–1594, 2001
Key concepts: Multiangle light scattering, Size-exclusion chromatography, Elution, Molar mass, Polymer, Chromatography, Gel permeation chromatography, Polystyrene