Noninvasive Quantitative Chromium(III) Speciation in Neat Solid Mixtures by Extended X-ray Absorption Fine Structure Spectroscopy

Marc M. Lamoureux, J. Craig. Hutton, David L. Styris, Richard Gordon

Open publisher page 5 citations

Abstract

A procedure that uses extended X-ray absorption fine structure (EXAFS) spectroscopy for quantitative chromium(III) speciation in neat solid mixtures is described. The procedure uses the full, filtered EXAFS, e.g., 4 ≤ k ≤ 12 Å −1 , rather than the smaller k-range associated with a single coordination sphere. Concentration is determined by a simple correlation of full, filtered EXAFS of standards with full, filtered EXAFS of mixtures. Under optimized conditions, calibration curves for mixtures of Cr 2 O 3 and Cr(NO 3 ) 3 ·9H 2 O have slopes of 1.002, respective intercepts of −0.7% and 0.5%, and correlation coefficients of 0.9991. Fluorescence EXAFS from mixtures must be compared to fluorescence EXAFS from standards, and the matrices and thicknesses of standards and mixtures must be closely matched. Transmission EXAFS of standards must be obtained to correct for self-absorption effects.

About this research paper

What this paper is about

A procedure that uses extended X-ray absorption fine structure (EXAFS) spectroscopy for quantitative chromium(III) speciation in neat solid mixtures is described. The procedure uses the full, filtered EXAFS, e.g., 4 ≤ k ≤ 12 Å −1 , rather than the smaller k-range associated with a single coordination sphere. Concentration is determined by a simple correlation of full, filtered EXAFS of standards with full, filtered EXAFS of mixtures. Under optimized conditions, calibration curves for mixtures of Cr 2 O 3 and Cr(NO 3 ) 3 ·9H 2 O have slopes of 1.002, respective intercepts of −0.7% and 0.5%, and correlation coefficients of 0.9991. Fluorescence EXAFS from mixtures must be compared to fluorescence EXAFS from standards, and the matrices and thicknesses of standards and mixtures must be closely matched. Transmission EXAFS of standards must be obtained to correct for self-absorption effects.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A procedure that uses extended X-ray absorption fine structure (EXAFS) spectroscopy for quantitative chromium(III) speciation in neat solid mixtures is described. The procedure uses the full, filtered EXAFS, e.g., 4 ≤ k ≤ 12 Å −1 , rather than the smaller k-range associated with a single coordination sphere. Concentration is determined by a simple correlation of full, filtered EXAFS of standards with full, filtered EXAFS of mixtures. Under optimized conditions, calibration curves for mixtures of Cr 2 O 3 and Cr(NO 3 ) 3 ·9H 2 O have slopes of 1.002, respective intercepts of −0.7% and 0.5%, and correlation coefficients of 0.9991. Fluorescence EXAFS from mixtures must be compared to fluorescence EXAFS from standards, and the matrices and thicknesses of standards and mixtures must be closely matched. Transmission EXAFS of standards must be obtained to correct for self-absorption effects.

Key concepts: Extended X-ray absorption fine structure, Absorption (acoustics), Chemistry, Analytical Chemistry (journal), Spectroscopy, Surface-extended X-ray absorption fine structure, Chromium, Absorption spectroscopy