2012Energy ProcediaOpen access

Research on Harmonic Suppression in Power System Based on Improved Adaptive Filter

Lingquan Zeng, Xin Li

Open full text 11 citations

Abstract

This paper described the structure of a Shunt Active Power Filter system and compared various methods of active power filter harmonic detection, then the improved adaptive algorithm was used in active power filter harmonic detection; as regards the control strategy, the control method that based on optimal voltage space vector hysteresis current was presented in this paper for tracking control, And by using Matlab/Simulink simulation software, the Adaptive filter detection system and control model of Three-phase three-wire Shunt Active Power Filter were established. Simulation results showed that the selected detection method and control strategy of harmonic current played a fairly good compensation role on the harmonics which was generated by nonlinear loads and had a good dynamic compensation performance.

About this research paper

What this paper is about

This paper described the structure of a Shunt Active Power Filter system and compared various methods of active power filter harmonic detection, then the improved adaptive algorithm was used in active power filter harmonic detection; as regards the control strategy, the control method that based on optimal voltage space vector hysteresis current was presented in this paper for tracking control, And by using Matlab/Simulink simulation software, the Adaptive filter detection system and control model of Three-phase three-wire Shunt Active Power Filter were established. Simulation results showed that the selected detection method and control strategy of harmonic current played a fairly good compensation role on the harmonics which was generated by nonlinear loads and had a good dynamic compensation performance.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper described the structure of a Shunt Active Power Filter system and compared various methods of active power filter harmonic detection, then the improved adaptive algorithm was used in active power filter harmonic detection; as regards the control strategy, the control method that based on optimal voltage space vector hysteresis current was presented in this paper for tracking control, And by using Matlab/Simulink simulation software, the Adaptive filter detection system and control model of Three-phase three-wire Shunt Active Power Filter were established. Simulation results showed that the selected detection method and control strategy of harmonic current played a fairly good compensation role on the harmonics which was generated by nonlinear loads and had a good dynamic compensation performance.

Key concepts: Control theory (sociology), Harmonics, Active filter, Harmonic, MATLAB, AC power, Compensation (psychology), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on Harmonic Suppression in Power System Based on Improved Adaptive Filter — Research Paper | ScholarLens