1997Review of Scientific InstrumentsRequires access

Measurement of heat capacity by fitting the whole temperature response of a heat-pulse calorimeter

Jih Shang Hwang, Kai Jan Lin, Cheng Tien

Open publisher page 266 citations

Abstract

A new method that fits the whole temperature response of a heat-pulse calorimeter for heat capacity is developed. Analyzing the thermal response of a heat-pulse calorimeter on a model that was used by the relaxation method, the authors derived some useful relations and further utilized the numeric method of the general linear least squares to determine the heat capacity of a sample. Absolute accuracy of the proposed method was verified by determining the heat capacity of a 0.249 76 g copper sample (purity 99.999%) on a self-designed and fully automated calorimetric system from 4.5 to 80 K. Comparing the result with the literature, the deviation in average was 1.2% from 4.5 to 20 K and 2.0% from 20 to 80 K. It is found that the proposed method is capable of measuring heat capacity regardless if the sample is adiabatically or nonadiabatically isolated. The size of the specimen is not critical for the application of the method and the temperature range of measurement can be expanded. It also deals with the τ2 effect. Details of the employed calorimetric system are described. Stability, inherent limitations, and further improvement of the system are also discussed.

About this research paper

What this paper is about

A new method that fits the whole temperature response of a heat-pulse calorimeter for heat capacity is developed. Analyzing the thermal response of a heat-pulse calorimeter on a model that was used by the relaxation method, the authors derived some useful relations and further utilized the numeric method of the general linear least squares to determine the heat capacity of a sample. Absolute accuracy of the proposed method was verified by determining the heat capacity of a 0.249 76 g copper sample (purity 99.999%) on a self-designed and fully automated calorimetric system from 4.5 to 80 K. Comparing the result with the literature, the deviation in average was 1.2% from 4.5 to 20 K and 2.0% from 20 to 80 K. It is found that the proposed method is capable of measuring heat capacity regardless if the sample is adiabatically or nonadiabatically isolated. The size of the specimen is not critical for the application of the method and the temperature range of measurement can be expanded. It also deals with the τ2 effect. Details of the employed calorimetric system are described. Stability, inherent limitations, and further improvement of the system are also discussed.

Why it matters

OpenAlex reports 266 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method that fits the whole temperature response of a heat-pulse calorimeter for heat capacity is developed. Analyzing the thermal response of a heat-pulse calorimeter on a model that was used by the relaxation method, the authors derived some useful relations and further utilized the numeric method of the general linear least squares to determine the heat capacity of a sample. Absolute accuracy of the proposed method was verified by determining the heat capacity of a 0.249 76 g copper sample (purity 99.999%) on a self-designed and fully automated calorimetric system from 4.5 to 80 K. Comparing the result with the literature, the deviation in average was 1.2% from 4.5 to 20 K and 2.0% from 20 to 80 K. It is found that the proposed method is capable of measuring heat capacity regardless if the sample is adiabatically or nonadiabatically isolated. The size of the specimen is not critical for the application of the method and the temperature range of measurement can be expanded. It also deals with the τ2 effect. Details of the employed calorimetric system are described. Stability, inherent limitations, and further improvement of the system are also discussed.

Key concepts: Calorimeter (particle physics), Heat capacity, Calorimeter constant, Materials science, Thermodynamics, Volumetric heat capacity, Calorimetry, Sample (material)

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of heat capacity by fitting the whole temperature response of a heat-pulse calorimeter — Research Paper | ScholarLens