Endoscopic ultrasound guided fine needle aspiration of solid pancreatic lesions: Performance and outcomes
Leon Fisher, Dev Segarajasingam, Colin Stewart, W Bastiaan Deboer, Ian F. Yusoff
Abstract
Leon Fisher, Dev Segarajasingam, Colin Stewart, W Bastiaan Deboer, Ian F. Yusoff
Abstract
BACKGROUND AND AIM: We report our single-centre experience with endoscopic ultrasound guided fine needle aspiration (EUS-FNA) of solid pancreatic lesions with regard to clinical utility, diagnostic accuracy and safety. METHODS: We prospectively reviewed data on 100 consecutive EUS-FNA procedures performed in 93 patients (54 men, mean age 60.6 +/- 12.9 years) for evaluation of solid pancreatic lesions. Final diagnosis was based on a composite standard: histologic evidence at surgery, or non-equivocal malignant cytology on FNA and follow-up. The operating characteristics of EUS-FNA were determined. RESULTS: The location of the lesions was pancreatic head in 73% of cases, the body in 20% and the tail in 7%. Mean lesion size was 35.1 +/- 12.9 mm. The final diagnosis revealed malignancy in 87 cases, including adenocarcinomas (80.5%), neuroendocrine tumours (11.5%), lymphomas (3.4%) and other types (4.6%). The FNA findings were: 82% interpreted as malignant cytology, 1% as suspicious for neoplasia, 1% as atypical, 7% as benign process and 9% as non-diagnostic. No false-positive results were observed. There was a false-negative rate of 5%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 94.3%, 100%, 100%, 72.2% and 95%, respectively. In 23 (88.5%) of 26 aspirated lymph nodes malignancy was found. Minor complications occurred in two patients. CONCLUSIONS: Our experience confirms that EUS-FNA in patients with suspected solid pancreatic lesions is safe and has a high diagnostic accuracy. This technique should be considered the preferred test when a cytological diagnosis of a pancreatic mass lesion is required.
OpenAlex reports 88 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND AND AIM: We report our single-centre experience with endoscopic ultrasound guided fine needle aspiration (EUS-FNA) of solid pancreatic lesions with regard to clinical utility, diagnostic accuracy and safety. METHODS: We prospectively reviewed data on 100 consecutive EUS-FNA procedures performed in 93 patients (54 men, mean age 60.6 +/- 12.9 years) for evaluation of solid pancreatic lesions. Final diagnosis was based on a composite standard: histologic evidence at surgery, or non-equivocal malignant cytology on FNA and follow-up. The operating characteristics of EUS-FNA were determined. RESULTS: The location of the lesions was pancreatic head in 73% of cases, the body in 20% and the tail in 7%. Mean lesion size was 35.1 +/- 12.9 mm. The final diagnosis revealed malignancy in 87 cases, including adenocarcinomas (80.5%), neuroendocrine tumours (11.5%), lymphomas (3.4%) and other types (4.6%). The FNA findings were: 82% interpreted as malignant cytology, 1% as suspicious for neoplasia, 1% as atypical, 7% as benign process and 9% as non-diagnostic. No false-positive results were observed. There was a false-negative rate of 5%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 94.3%, 100%, 100%, 72.2% and 95%, respectively. In 23 (88.5%) of 26 aspirated lymph nodes malignancy was found. Minor complications occurred in two patients. CONCLUSIONS: Our experience confirms that EUS-FNA in patients with suspected solid pancreatic lesions is safe and has a high diagnostic accuracy. This technique should be considered the preferred test when a cytological diagnosis of a pancreatic mass lesion is required.
Key concepts: Medicine, Endoscopic ultrasound, Malignancy, Fine-needle aspiration, Radiology, Cytology, Cytopathology, Diagnostic accuracy