2015•Cardiovascular SystemOpen access

Elliptic st. jude bileaflet mechanical heart valves

Hadi Mohammadi, Mehdi Jahandardoost, Guy J. Fradet

Open full text 5 citations

Abstract

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977.The SJM valve design consists of two semicircular leaflets which pivot on hinges.Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the valve is trivial.However, non-physiological hemodynamics around these valves may lead to red blood cells lysis and therombigenic complications.Also, the regurgitation-flow inSJM valves is almost twice that of the native valves in the aortic position.In this study, we suggest a new design for the stent (housing) of SJM valves in which 15% ovality is applied to the stent whereas its perimeter remains constant.In a pilot study, the hemodynamic performance of the proposed design is analyzed in the closing phaseand compared to that of conventional SJM models.Results show that while the elliptic SJM model offers a shorter closing phase (9.7% shorter), the regurgitation flow remains almost unchanged.In other words, even though the dynamic response of the valve is improved, the regurgitation flow is not decreased.Thus, a more efficient effective orifice area (EOA) is shown to be provided by the proposed model.The preliminary calculations presented in this study justify an improved hemodynamics of elliptic SJM valves compared to conventional models; the proposed design shows promise and merits further development.

Open-access reader

About this research paper

What this paper is about

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977.The SJM valve design consists of two semicircular leaflets which pivot on hinges.Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the valve is trivial.However, non-physiological hemodynamics around these valves may lead to red blood cells lysis and therombigenic complications.Also, the regurgitation-flow inSJM valves is almost twice that of the native valves in the aortic position.In this study, we suggest a new design for the stent (housing) of SJM valves in which 15% ovality is applied to the stent whereas its perimeter remains constant.In a pilot study, the hemodynamic performance of the proposed design is analyzed in the closing phaseand compared to that of conventional SJM models.Results show that while the elliptic SJM model offers a shorter closing phase (9.7% shorter), the regurgitation flow remains almost unchanged.In other words, even though the dynamic response of the valve is improved, the regurgitation flow is not decreased.Thus, a more efficient effective orifice area (EOA) is shown to be provided by the proposed model.The preliminary calculations presented in this study justify an improved hemodynamics of elliptic SJM valves compared to conventional models; the proposed design shows promise and merits further development.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977.The SJM valve design consists of two semicircular leaflets which pivot on hinges.Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the valve is trivial.However, non-physiological hemodynamics around these valves may lead to red blood cells lysis and therombigenic complications.Also, the regurgitation-flow inSJM valves is almost twice that of the native valves in the aortic position.In this study, we suggest a new design for the stent (housing) of SJM valves in which 15% ovality is applied to the stent whereas its perimeter remains constant.In a pilot study, the hemodynamic performance of the proposed design is analyzed in the closing phaseand compared to that of conventional SJM models.Results show that while the elliptic SJM model offers a shorter closing phase (9.7% shorter), the regurgitation flow remains almost unchanged.In other words, even though the dynamic response of the valve is improved, the regurgitation flow is not decreased.Thus, a more efficient effective orifice area (EOA) is shown to be provided by the proposed model.The preliminary calculations presented in this study justify an improved hemodynamics of elliptic SJM valves compared to conventional models; the proposed design shows promise and merits further development.

Key concepts: Mechanical heart, Mechanical heart-valve, Cardiology, Internal medicine, Medicine, Heart valve