1999ThoraxOpen access

Effect of brachial plexus co-activation on phrenic nerve conduction time

Yuan Luo, Michael I. Polkey, Rebecca Lyall, John Moxham

Open full text 25 citations

Abstract

BACKGROUND: Diaphragm function can be assessed by electromyography of the diaphragm during electrical phrenic nerve stimulation (ES). Whether phrenic nerve conduction time (PNCT) and diaphragm electrical activity can be reliably measured from chest wall electrodes with ES is uncertain. METHODS: The diaphragm compound muscle action potential (CMAP) was recorded using an oesophageal electrode and lower chest wall electrodes during ES in six normal subjects. Two patients with bilateral diaphragm paralysis were also studied. Stimulations were deliberately given in a manner designed to avoid or incur co-activation of the brachial plexus. RESULTS: For the oesophageal electrode the PNCT was similar with both stimulation techniques with mean (SE) values of 7.1 (0.2) and 6.8 (0.2) ms, respectively (pooled left and right values). However, for surface electrodes the PNCT was substantially shorter when the brachial plexus was activated (4.4 (0.1) ms) than when it was not (7.4 (0.2) ms) (mean difference 3.0 ms, 95% CI 2.7 to 3.4, p<0.0001). A small short latency CMAP was recorded from the lower chest wall electrodes during stimulation of the brachial plexus alone. CONCLUSIONS: The results of this study show that lower chest wall electrodes only accurately measure PNCT when care is taken to avoid stimulating the brachial plexus. A false positive CMAP response to phrenic stimulation could be caused by inadvertent stimulation of the brachial plexus. This finding may further explain why the diaphragm CMAP recorded from chest wall electrodes can be unreliable with cervical magnetic stimulation during which brachial plexus activation occurs.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Diaphragm function can be assessed by electromyography of the diaphragm during electrical phrenic nerve stimulation (ES). Whether phrenic nerve conduction time (PNCT) and diaphragm electrical activity can be reliably measured from chest wall electrodes with ES is uncertain. METHODS: The diaphragm compound muscle action potential (CMAP) was recorded using an oesophageal electrode and lower chest wall electrodes during ES in six normal subjects. Two patients with bilateral diaphragm paralysis were also studied. Stimulations were deliberately given in a manner designed to avoid or incur co-activation of the brachial plexus. RESULTS: For the oesophageal electrode the PNCT was similar with both stimulation techniques with mean (SE) values of 7.1 (0.2) and 6.8 (0.2) ms, respectively (pooled left and right values). However, for surface electrodes the PNCT was substantially shorter when the brachial plexus was activated (4.4 (0.1) ms) than when it was not (7.4 (0.2) ms) (mean difference 3.0 ms, 95% CI 2.7 to 3.4, p<0.0001). A small short latency CMAP was recorded from the lower chest wall electrodes during stimulation of the brachial plexus alone. CONCLUSIONS: The results of this study show that lower chest wall electrodes only accurately measure PNCT when care is taken to avoid stimulating the brachial plexus. A false positive CMAP response to phrenic stimulation could be caused by inadvertent stimulation of the brachial plexus. This finding may further explain why the diaphragm CMAP recorded from chest wall electrodes can be unreliable with cervical magnetic stimulation during which brachial plexus activation occurs.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Diaphragm function can be assessed by electromyography of the diaphragm during electrical phrenic nerve stimulation (ES). Whether phrenic nerve conduction time (PNCT) and diaphragm electrical activity can be reliably measured from chest wall electrodes with ES is uncertain. METHODS: The diaphragm compound muscle action potential (CMAP) was recorded using an oesophageal electrode and lower chest wall electrodes during ES in six normal subjects. Two patients with bilateral diaphragm paralysis were also studied. Stimulations were deliberately given in a manner designed to avoid or incur co-activation of the brachial plexus. RESULTS: For the oesophageal electrode the PNCT was similar with both stimulation techniques with mean (SE) values of 7.1 (0.2) and 6.8 (0.2) ms, respectively (pooled left and right values). However, for surface electrodes the PNCT was substantially shorter when the brachial plexus was activated (4.4 (0.1) ms) than when it was not (7.4 (0.2) ms) (mean difference 3.0 ms, 95% CI 2.7 to 3.4, p<0.0001). A small short latency CMAP was recorded from the lower chest wall electrodes during stimulation of the brachial plexus alone. CONCLUSIONS: The results of this study show that lower chest wall electrodes only accurately measure PNCT when care is taken to avoid stimulating the brachial plexus. A false positive CMAP response to phrenic stimulation could be caused by inadvertent stimulation of the brachial plexus. This finding may further explain why the diaphragm CMAP recorded from chest wall electrodes can be unreliable with cervical magnetic stimulation during which brachial plexus activation occurs.

Key concepts: Medicine, Brachial plexus, Phrenic nerve, Diaphragm (acoustics), Stimulation, Compound muscle action potential, Anesthesia, Electromyography