2014International Journal of PhotoenergyOpen access

A Communication Based Islanding Detection Method for Photovoltaic Distributed Generation Systems

Gökay Bayrak, Mehmet Cebeci

Open full text 19 citations

Abstract

PV based distributed generation (DG) systems must have some electrical connection standards while they connected to an electrical grid. One of these electrical conditions and the most important one is unplanned islanding condition. Islanding is a very dangerous condition because it could damage the PV system and related electrical systems and also working people have been at risk in islanding condition. In this application study, a new communication based islanding detection method was introduced for grid tied PV systems. A real time controller was developed with Labview for detecting islanding condition. Developed method is a hybrid method which uses the effective ways of communication based and passive methods. The results obtained from the proposed real time islanding detection method show that proposed method is reliable, robust, and independent from load and inverter. Nondetection zone (NDZ) is almost zero and islanding detection time is approximately 1-2 cycles indicated in experimental results so this time has a significant short response time according to IEEE 929-2000 standard. The proposed method is effective and presents a realistic solution to islanding so it could be implemented easily to grid tied PV systems and could be used in real system applications.

Open-access reader

About this research paper

What this paper is about

PV based distributed generation (DG) systems must have some electrical connection standards while they connected to an electrical grid. One of these electrical conditions and the most important one is unplanned islanding condition. Islanding is a very dangerous condition because it could damage the PV system and related electrical systems and also working people have been at risk in islanding condition. In this application study, a new communication based islanding detection method was introduced for grid tied PV systems. A real time controller was developed with Labview for detecting islanding condition. Developed method is a hybrid method which uses the effective ways of communication based and passive methods. The results obtained from the proposed real time islanding detection method show that proposed method is reliable, robust, and independent from load and inverter. Nondetection zone (NDZ) is almost zero and islanding detection time is approximately 1-2 cycles indicated in experimental results so this time has a significant short response time according to IEEE 929-2000 standard. The proposed method is effective and presents a realistic solution to islanding so it could be implemented easily to grid tied PV systems and could be used in real system applications.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PV based distributed generation (DG) systems must have some electrical connection standards while they connected to an electrical grid. One of these electrical conditions and the most important one is unplanned islanding condition. Islanding is a very dangerous condition because it could damage the PV system and related electrical systems and also working people have been at risk in islanding condition. In this application study, a new communication based islanding detection method was introduced for grid tied PV systems. A real time controller was developed with Labview for detecting islanding condition. Developed method is a hybrid method which uses the effective ways of communication based and passive methods. The results obtained from the proposed real time islanding detection method show that proposed method is reliable, robust, and independent from load and inverter. Nondetection zone (NDZ) is almost zero and islanding detection time is approximately 1-2 cycles indicated in experimental results so this time has a significant short response time according to IEEE 929-2000 standard. The proposed method is effective and presents a realistic solution to islanding so it could be implemented easily to grid tied PV systems and could be used in real system applications.

Key concepts: Islanding, Photovoltaic system, Inverter, Computer science, Grid, Distributed generation, Electronic engineering, Controller (irrigation)

Related papers

Back to paper searchBrowse research topicsOriginal source
A Communication Based Islanding Detection Method for Photovoltaic Distributed Generation Systems — Research Paper | ScholarLens