2005Liver TransplantationRequires access

Rapid, large-scale formation of porcine hepatocyte spheroids in a novel spheroid reservoir bioartificial liver

Scott L. Nyberg, Joseph A. Hardin, Bruce Amiot, Upendra A. Argikar, Rory P. Remmel, Piero Rinaldo

Open publisher page 144 citations

Abstract

We have developed a novel bioreactor based on the observation that isolated porcine hepatocytes rapidly and spontaneously aggregate into spheroids under oscillation conditions. The purpose of this study was to characterize the influence of oscillation frequency (0.125 Hz, 0.25 Hz), cell density (1-10 x 10(6) cells/mL), and storage condition (fresh, cryopreserved) of porcine hepatocytes on the kinetics of spheroid formation. The viability and metabolic performance of spheroid hepatocytes was also compared to monolayer culture. We observed that both fresh and cryopreserved porcine hepatocytes began formation of spheroids spontaneously at the onset of oscillation culture. Spheroid size was directly related to cell density and time in culture, though inversely related to oscillatory frequency. Spheroid formation by fresh porcine hepatocytes was associated with decreased cell death (lactate dehydrogenase release, 1.3 +/- 1.0 vs. 3.1 +/- 0.7 U/mL, P < 0.05) and increased metabolic performance (albumin production, 14.7 +/- 3.3 vs. 4.6 +/- 1.4 fg/c/h, P < 0.0001; ureagenesis from ammonia, 267 +/- 63 vs. 92 +/- 13 micromol/L/h, P < 0.001) compared with monolayer culture. In conclusion, based on the favorable properties of rapid spheroid formation, increased hepatocellular function, and ease of scale-up, the spheroid reservoir bioreactor warrants further investigation as a bioartificial liver for support of liver failure.

About this research paper

What this paper is about

We have developed a novel bioreactor based on the observation that isolated porcine hepatocytes rapidly and spontaneously aggregate into spheroids under oscillation conditions. The purpose of this study was to characterize the influence of oscillation frequency (0.125 Hz, 0.25 Hz), cell density (1-10 x 10(6) cells/mL), and storage condition (fresh, cryopreserved) of porcine hepatocytes on the kinetics of spheroid formation. The viability and metabolic performance of spheroid hepatocytes was also compared to monolayer culture. We observed that both fresh and cryopreserved porcine hepatocytes began formation of spheroids spontaneously at the onset of oscillation culture. Spheroid size was directly related to cell density and time in culture, though inversely related to oscillatory frequency. Spheroid formation by fresh porcine hepatocytes was associated with decreased cell death (lactate dehydrogenase release, 1.3 +/- 1.0 vs. 3.1 +/- 0.7 U/mL, P < 0.05) and increased metabolic performance (albumin production, 14.7 +/- 3.3 vs. 4.6 +/- 1.4 fg/c/h, P < 0.0001; ureagenesis from ammonia, 267 +/- 63 vs. 92 +/- 13 micromol/L/h, P < 0.001) compared with monolayer culture. In conclusion, based on the favorable properties of rapid spheroid formation, increased hepatocellular function, and ease of scale-up, the spheroid reservoir bioreactor warrants further investigation as a bioartificial liver for support of liver failure.

Why it matters

OpenAlex reports 144 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a novel bioreactor based on the observation that isolated porcine hepatocytes rapidly and spontaneously aggregate into spheroids under oscillation conditions. The purpose of this study was to characterize the influence of oscillation frequency (0.125 Hz, 0.25 Hz), cell density (1-10 x 10(6) cells/mL), and storage condition (fresh, cryopreserved) of porcine hepatocytes on the kinetics of spheroid formation. The viability and metabolic performance of spheroid hepatocytes was also compared to monolayer culture. We observed that both fresh and cryopreserved porcine hepatocytes began formation of spheroids spontaneously at the onset of oscillation culture. Spheroid size was directly related to cell density and time in culture, though inversely related to oscillatory frequency. Spheroid formation by fresh porcine hepatocytes was associated with decreased cell death (lactate dehydrogenase release, 1.3 +/- 1.0 vs. 3.1 +/- 0.7 U/mL, P < 0.05) and increased metabolic performance (albumin production, 14.7 +/- 3.3 vs. 4.6 +/- 1.4 fg/c/h, P < 0.0001; ureagenesis from ammonia, 267 +/- 63 vs. 92 +/- 13 micromol/L/h, P < 0.001) compared with monolayer culture. In conclusion, based on the favorable properties of rapid spheroid formation, increased hepatocellular function, and ease of scale-up, the spheroid reservoir bioreactor warrants further investigation as a bioartificial liver for support of liver failure.

Key concepts: Spheroid, Bioartificial liver device, Medicine, Hepatocyte, Liver transplantation, Artificial liver, Liver failure, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid, large-scale formation of porcine hepatocyte spheroids in a novel spheroid reservoir bioartificial liver — Research Paper | ScholarLens