1972Organic Mass SpectrometryRequires access

Field desorption mass spectrometry with high temperature activated emitters

H.‐R. SCHULTEN, H. D. Beckey

Open publisher page 200 citations

Abstract

Abstract The use of emitters which have been activated at high temperature in Field Ionization and Field Desorption mass spectrometry offers some important advantages over the usual emitter type activated at room‐temperature. Higher thermal stability of the microneedles is achieved and the emitters are extremely resistant to chemical attack. It becomes possible to induce a thermal fragmentation of solid compounds adsorbed on the emitter surface between room‐temperature and approximately 2000°C. The field anodes may be re‐used many times without loss of quality. The problem of mass references is solved in Field Ionization/Field Desorption‐Mass Spectrometry when high temperature emitters are used. The Field Ionization mass spectra of perfluorokerosene (PFK) and perfluorotributylamine display peaks in the mass range between m/e 50 to 800, with a resolution of up to 30000 (10% valley definition). A short description of a rapid and easy activation to produce high temperature microneedles is given. The following abbreviations are used throughout this paper:— HT High Temperature RT Room‐Temperature BAT Best Anode Temperature HR High Resolution MS Mass Spectrometry/Spectrum/Spectra EI Electron Impact FI Field Ionization CI Chemical Ionization FD Field Desorption

About this research paper

What this paper is about

Abstract The use of emitters which have been activated at high temperature in Field Ionization and Field Desorption mass spectrometry offers some important advantages over the usual emitter type activated at room‐temperature. Higher thermal stability of the microneedles is achieved and the emitters are extremely resistant to chemical attack. It becomes possible to induce a thermal fragmentation of solid compounds adsorbed on the emitter surface between room‐temperature and approximately 2000°C. The field anodes may be re‐used many times without loss of quality. The problem of mass references is solved in Field Ionization/Field Desorption‐Mass Spectrometry when high temperature emitters are used. The Field Ionization mass spectra of perfluorokerosene (PFK) and perfluorotributylamine display peaks in the mass range between m/e 50 to 800, with a resolution of up to 30000 (10% valley definition). A short description of a rapid and easy activation to produce high temperature microneedles is given. The following abbreviations are used throughout this paper:— HT High Temperature RT Room‐Temperature BAT Best Anode Temperature HR High Resolution MS Mass Spectrometry/Spectrum/Spectra EI Electron Impact FI Field Ionization CI Chemical Ionization FD Field Desorption

Why it matters

OpenAlex reports 200 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The use of emitters which have been activated at high temperature in Field Ionization and Field Desorption mass spectrometry offers some important advantages over the usual emitter type activated at room‐temperature. Higher thermal stability of the microneedles is achieved and the emitters are extremely resistant to chemical attack. It becomes possible to induce a thermal fragmentation of solid compounds adsorbed on the emitter surface between room‐temperature and approximately 2000°C. The field anodes may be re‐used many times without loss of quality. The problem of mass references is solved in Field Ionization/Field Desorption‐Mass Spectrometry when high temperature emitters are used. The Field Ionization mass spectra of perfluorokerosene (PFK) and perfluorotributylamine display peaks in the mass range between m/e 50 to 800, with a resolution of up to 30000 (10% valley definition). A short description of a rapid and easy activation to produce high temperature microneedles is given. The following abbreviations are used throughout this paper:— HT High Temperature RT Room‐Temperature BAT Best Anode Temperature HR High Resolution MS Mass Spectrometry/Spectrum/Spectra EI Electron Impact FI Field Ionization CI Chemical Ionization FD Field Desorption

Key concepts: Field desorption, Mass spectrometry, Thermal ionization mass spectrometry, Analytical Chemistry (journal), Thermal ionization, Desorption, Desorption electrospray ionization, Thermal desorption