2008•BMC MicrobiologyOpen access

Sensitive and rapid detection of cholera toxin-producing Vibrio cholerae using a loop-mediated isothermal amplification

Wataru Yamazaki, Kazuko Seto, Masumi Taguchi, Masanori Ishibashi, Kiyoshi Inoue

Open full text 93 citations

Abstract

BACKGROUND: Vibrio cholerae is widely acknowledged as one of the most important waterborne pathogen causing gastrointestinal disorders. Cholera toxin (CT) is a major virulence determinant of V. cholerae. Detection of CT-producing V. cholerae using conventional culture-, biochemical- and immunological-based assays is time-consuming and laborious, requiring more than three days. Thus, we developed a novel and highly specific loop-mediated isothermal amplification (LAMP) assay for the sensitive and rapid detection of cholera toxin (CT)-producing Vibrio cholerae. RESULTS: The assay provided markedly more sensitive and rapid detection of CT-producing V. cholerae strains than conventional biochemical and PCR assays. The assay correctly identified 34 CT-producing V. cholerae strains, but did not detect 13 CT non-producing V. cholerae and 53 non-V. cholerae strains. Sensitivity of the LAMP assay for direct detection of CT-producing V. cholerae in spiked human feces was 7.8 x 102 CFU per g (1.4 CFU per reaction). The sensitivity of the LAMP assay was 10-fold more sensitive than that of the conventional PCR assay. The LAMP assay for detection of CT-producing V. cholerae required less than 35 min with a single colony on thiosulfate citrate bile salt sucrose (TCBS) agar and 70 min with human feces from the beginning of DNA extraction to final determination. CONCLUSION: The LAMP assay is a sensitive, rapid and simple tool for the detection of CT-producing V. cholerae and will be useful in facilitating the early diagnosis of human V. cholerae infection.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Vibrio cholerae is widely acknowledged as one of the most important waterborne pathogen causing gastrointestinal disorders. Cholera toxin (CT) is a major virulence determinant of V. cholerae. Detection of CT-producing V. cholerae using conventional culture-, biochemical- and immunological-based assays is time-consuming and laborious, requiring more than three days. Thus, we developed a novel and highly specific loop-mediated isothermal amplification (LAMP) assay for the sensitive and rapid detection of cholera toxin (CT)-producing Vibrio cholerae. RESULTS: The assay provided markedly more sensitive and rapid detection of CT-producing V. cholerae strains than conventional biochemical and PCR assays. The assay correctly identified 34 CT-producing V. cholerae strains, but did not detect 13 CT non-producing V. cholerae and 53 non-V. cholerae strains. Sensitivity of the LAMP assay for direct detection of CT-producing V. cholerae in spiked human feces was 7.8 x 102 CFU per g (1.4 CFU per reaction). The sensitivity of the LAMP assay was 10-fold more sensitive than that of the conventional PCR assay. The LAMP assay for detection of CT-producing V. cholerae required less than 35 min with a single colony on thiosulfate citrate bile salt sucrose (TCBS) agar and 70 min with human feces from the beginning of DNA extraction to final determination. CONCLUSION: The LAMP assay is a sensitive, rapid and simple tool for the detection of CT-producing V. cholerae and will be useful in facilitating the early diagnosis of human V. cholerae infection.

Why it matters

OpenAlex reports 93 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Vibrio cholerae is widely acknowledged as one of the most important waterborne pathogen causing gastrointestinal disorders. Cholera toxin (CT) is a major virulence determinant of V. cholerae. Detection of CT-producing V. cholerae using conventional culture-, biochemical- and immunological-based assays is time-consuming and laborious, requiring more than three days. Thus, we developed a novel and highly specific loop-mediated isothermal amplification (LAMP) assay for the sensitive and rapid detection of cholera toxin (CT)-producing Vibrio cholerae. RESULTS: The assay provided markedly more sensitive and rapid detection of CT-producing V. cholerae strains than conventional biochemical and PCR assays. The assay correctly identified 34 CT-producing V. cholerae strains, but did not detect 13 CT non-producing V. cholerae and 53 non-V. cholerae strains. Sensitivity of the LAMP assay for direct detection of CT-producing V. cholerae in spiked human feces was 7.8 x 102 CFU per g (1.4 CFU per reaction). The sensitivity of the LAMP assay was 10-fold more sensitive than that of the conventional PCR assay. The LAMP assay for detection of CT-producing V. cholerae required less than 35 min with a single colony on thiosulfate citrate bile salt sucrose (TCBS) agar and 70 min with human feces from the beginning of DNA extraction to final determination. CONCLUSION: The LAMP assay is a sensitive, rapid and simple tool for the detection of CT-producing V. cholerae and will be useful in facilitating the early diagnosis of human V. cholerae infection.

Key concepts: Vibrio cholerae, Loop-mediated isothermal amplification, Microbiology, Cholera toxin, Biology, Cholera, El Tor, Vibrionaceae

Related papers

Back to paper searchBrowse research topicsOriginal source
Sensitive and rapid detection of cholera toxin-producing Vibrio cholerae using a loop-mediated isothermal amplification — Research Paper | ScholarLens