Flocculant Screening for the Pretreatment of Printing and Dyeing Wastewater
Shan Hong Lan, Ping Ma, Shi Wen Geng, Jia Hao Sun, Hui Xia Lan, Heng Zhang
Abstract
Shan Hong Lan, Ping Ma, Shi Wen Geng, Jia Hao Sun, Hui Xia Lan, Heng Zhang
Abstract
Study on the pretreatment of printing and dyeing wastewater with PAC、Fe2(SO4)3and FeCl3was carried out. Effects of the flocculants dosage, pH on the treatment efficiency were studied. The results showed that with PAC, Fe2(SO4)3and the FeCl3dosage rising, the treatment effect first decreased and then increased and when the addition amount was 300 mg.L-1、300mg.L-1and 250 mg.L-1,the COD removal efficiency achieved 69%、78%、74% , respectively. With the rising of pH, the treatment effects of the three types of flocculants increased first and then decreased, the optimum pH of PAC and Fe2(SO4)3was 7and the best pH of FeCl3was 6. At last, the settle ability and the amount of the producing floc were studied, the results showed that the settle ability was the best and the least amount of sludge produced by FeCl3flocculation. Keywords: printing and dyeing wastewater, pretreatment, flocculants, screening.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Study on the pretreatment of printing and dyeing wastewater with PAC、Fe2(SO4)3and FeCl3was carried out. Effects of the flocculants dosage, pH on the treatment efficiency were studied. The results showed that with PAC, Fe2(SO4)3and the FeCl3dosage rising, the treatment effect first decreased and then increased and when the addition amount was 300 mg.L-1、300mg.L-1and 250 mg.L-1,the COD removal efficiency achieved 69%、78%、74% , respectively. With the rising of pH, the treatment effects of the three types of flocculants increased first and then decreased, the optimum pH of PAC and Fe2(SO4)3was 7and the best pH of FeCl3was 6. At last, the settle ability and the amount of the producing floc were studied, the results showed that the settle ability was the best and the least amount of sludge produced by FeCl3flocculation. Keywords: printing and dyeing wastewater, pretreatment, flocculants, screening.
Key concepts: Flocculation, Wastewater, Chemistry, Dyeing, Nuclear chemistry, Pulp and paper industry, Chromatography, Treatment effect