1996Emergency Medicine JournalOpen access

Changes in stroke distance in response to haemorrhage in a swine model.

Michael Clancy, Jonathan Alderman, N Cavallero, K J Taylor

Open full text 1 citations

Abstract

OBJECTIVE: To determine, using an animal model of blood loss, (1) if stroke distance, derived non-invasively from the time integral of the maximum velocity of red cells in the aorta, changed to a greater extent than heart rate and mean arterial pressure (MAP), which are recognised to be unreliable indicators of blood loss; (2) if changes in stroke distance reflected changes in stroke volume derived from thermodilution cardiac output measurements. METHODS: Eight anaesthetised swine had baseline measurements of heart rate, MAP, stroke volume, and stroke distance and were then exsanguinated at a rate of 1 ml/kg/min. Percentage changes from baseline of heart rate, MAP, stroke volume, and stroke distance were compared after 10, 20, and 30 ml/kg blood loss. The animal's blood was then reinfused at the rate of 2 ml/kg/min for 15 min, followed by normal saline 1 ml/kg/min. Percentage changes from baseline measurement of stroke volume and stroke distance over the whole experiment were evaluated by regression analysis. RESULTS: Heart rate, MAP, and stroke distance changed +7.9%, -22.5%, and -18.1% respectively (from baseline values) after 10 ml/kg blood loss; +23.2%, -44.0%, and -47.4% after 20 ml/kg blood loss; and +55.7%, -62.0%, and -69.8% after 30 ml/kg blood loss. Regression analysis of percentage changes in stroke volume and stroke distance from their baseline values at experimental time zero is stroke volume = 1.014 x stroke distance -2.156, r = 0.92, n = 54, P < 0.0001. CONCLUSIONS: (1) At maximal blood loss, stroke distance changes to a greater extent than heart rate and MAP. (2) Changes in stroke distance reflected changes in stroke volume but with less variability at lower values. Stroke distance may be a more useful measure of blood loss than heart rate and MAP.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: To determine, using an animal model of blood loss, (1) if stroke distance, derived non-invasively from the time integral of the maximum velocity of red cells in the aorta, changed to a greater extent than heart rate and mean arterial pressure (MAP), which are recognised to be unreliable indicators of blood loss; (2) if changes in stroke distance reflected changes in stroke volume derived from thermodilution cardiac output measurements. METHODS: Eight anaesthetised swine had baseline measurements of heart rate, MAP, stroke volume, and stroke distance and were then exsanguinated at a rate of 1 ml/kg/min. Percentage changes from baseline of heart rate, MAP, stroke volume, and stroke distance were compared after 10, 20, and 30 ml/kg blood loss. The animal's blood was then reinfused at the rate of 2 ml/kg/min for 15 min, followed by normal saline 1 ml/kg/min. Percentage changes from baseline measurement of stroke volume and stroke distance over the whole experiment were evaluated by regression analysis. RESULTS: Heart rate, MAP, and stroke distance changed +7.9%, -22.5%, and -18.1% respectively (from baseline values) after 10 ml/kg blood loss; +23.2%, -44.0%, and -47.4% after 20 ml/kg blood loss; and +55.7%, -62.0%, and -69.8% after 30 ml/kg blood loss. Regression analysis of percentage changes in stroke volume and stroke distance from their baseline values at experimental time zero is stroke volume = 1.014 x stroke distance -2.156, r = 0.92, n = 54, P < 0.0001. CONCLUSIONS: (1) At maximal blood loss, stroke distance changes to a greater extent than heart rate and MAP. (2) Changes in stroke distance reflected changes in stroke volume but with less variability at lower values. Stroke distance may be a more useful measure of blood loss than heart rate and MAP.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine, using an animal model of blood loss, (1) if stroke distance, derived non-invasively from the time integral of the maximum velocity of red cells in the aorta, changed to a greater extent than heart rate and mean arterial pressure (MAP), which are recognised to be unreliable indicators of blood loss; (2) if changes in stroke distance reflected changes in stroke volume derived from thermodilution cardiac output measurements. METHODS: Eight anaesthetised swine had baseline measurements of heart rate, MAP, stroke volume, and stroke distance and were then exsanguinated at a rate of 1 ml/kg/min. Percentage changes from baseline of heart rate, MAP, stroke volume, and stroke distance were compared after 10, 20, and 30 ml/kg blood loss. The animal's blood was then reinfused at the rate of 2 ml/kg/min for 15 min, followed by normal saline 1 ml/kg/min. Percentage changes from baseline measurement of stroke volume and stroke distance over the whole experiment were evaluated by regression analysis. RESULTS: Heart rate, MAP, and stroke distance changed +7.9%, -22.5%, and -18.1% respectively (from baseline values) after 10 ml/kg blood loss; +23.2%, -44.0%, and -47.4% after 20 ml/kg blood loss; and +55.7%, -62.0%, and -69.8% after 30 ml/kg blood loss. Regression analysis of percentage changes in stroke volume and stroke distance from their baseline values at experimental time zero is stroke volume = 1.014 x stroke distance -2.156, r = 0.92, n = 54, P < 0.0001. CONCLUSIONS: (1) At maximal blood loss, stroke distance changes to a greater extent than heart rate and MAP. (2) Changes in stroke distance reflected changes in stroke volume but with less variability at lower values. Stroke distance may be a more useful measure of blood loss than heart rate and MAP.

Key concepts: Medicine, Stroke volume, Stroke (engine), Heart rate, Blood pressure, Cardiac output, Blood volume, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes in stroke distance in response to haemorrhage in a swine model. — Research Paper | ScholarLens