1976Circulation ResearchOpen access

Effect of thoracic blood volume changes on steady state cardiac output.

Wayne Mitzner, Howard Goldberg, Samuel V. Lichtenstein

Open full text 26 citations

Abstract

We have investigated the extent to which shifts of blood volume out of or into the thoracic region influence the steady state cardiac output. The systemic circulation of anesthetized dogs was replaced with an artificial circuit which stimulated the pertinent mechanical characteristics of an intact circulation. As in the normal animal, the steady state venous return was proportional to the pressure gradient for venous return (i.e, mean systemic minus right atrial pressure). Cardiac function was altered either by administration of epinephrine or by changes in left ventricular afterload. At a constant mean aortic pressure of 100 mm Hg, epinephrine administration increased the steady state cardiac output by 55%. Half of this increase resulted from the lowered mean right atrial pressure (caused by improved cardiac function); the remainder resulted from an increased mean systemic pressure (caused by the volume shift to the systemic circulation). Increases in afterload transferred sufficient volume to the heart-lung compartment to reduce significantly the mean systemic pressure and, hence, the steady state venous return. Our results indicate that the heart-lung compartment contains a significant volume which is under cardiac control. In addition to being able to alter the right atrial pressure, the heart can modulate the steady state cardiac output by adjusting the mean systemic pressure. To this degree the heart can adjust its own venous return.

Open-access reader

About this research paper

What this paper is about

We have investigated the extent to which shifts of blood volume out of or into the thoracic region influence the steady state cardiac output. The systemic circulation of anesthetized dogs was replaced with an artificial circuit which stimulated the pertinent mechanical characteristics of an intact circulation. As in the normal animal, the steady state venous return was proportional to the pressure gradient for venous return (i.e, mean systemic minus right atrial pressure). Cardiac function was altered either by administration of epinephrine or by changes in left ventricular afterload. At a constant mean aortic pressure of 100 mm Hg, epinephrine administration increased the steady state cardiac output by 55%. Half of this increase resulted from the lowered mean right atrial pressure (caused by improved cardiac function); the remainder resulted from an increased mean systemic pressure (caused by the volume shift to the systemic circulation). Increases in afterload transferred sufficient volume to the heart-lung compartment to reduce significantly the mean systemic pressure and, hence, the steady state venous return. Our results indicate that the heart-lung compartment contains a significant volume which is under cardiac control. In addition to being able to alter the right atrial pressure, the heart can modulate the steady state cardiac output by adjusting the mean systemic pressure. To this degree the heart can adjust its own venous return.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have investigated the extent to which shifts of blood volume out of or into the thoracic region influence the steady state cardiac output. The systemic circulation of anesthetized dogs was replaced with an artificial circuit which stimulated the pertinent mechanical characteristics of an intact circulation. As in the normal animal, the steady state venous return was proportional to the pressure gradient for venous return (i.e, mean systemic minus right atrial pressure). Cardiac function was altered either by administration of epinephrine or by changes in left ventricular afterload. At a constant mean aortic pressure of 100 mm Hg, epinephrine administration increased the steady state cardiac output by 55%. Half of this increase resulted from the lowered mean right atrial pressure (caused by improved cardiac function); the remainder resulted from an increased mean systemic pressure (caused by the volume shift to the systemic circulation). Increases in afterload transferred sufficient volume to the heart-lung compartment to reduce significantly the mean systemic pressure and, hence, the steady state venous return. Our results indicate that the heart-lung compartment contains a significant volume which is under cardiac control. In addition to being able to alter the right atrial pressure, the heart can modulate the steady state cardiac output by adjusting the mean systemic pressure. To this degree the heart can adjust its own venous return.

Key concepts: Mean circulatory filling pressure, Venous return curve, Afterload, Cardiac output, Central venous pressure, Cardiology, Medicine, Blood volume

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of thoracic blood volume changes on steady state cardiac output. — Research Paper | ScholarLens