2014•Journal of Nuclear Science and TechnologyOpen access

Above-ground HTGR design for passive decay heat removal

Odmaa Sambuu, Toru Obara

Open full text 7 citations

Abstract

The design of a small high-temperature gas-cooled reactor (HTGR) for passive decay heat removal which could be located deeply underground was proposed previously. In the present work, analogue design analyses of passive decay heat removal for an above-ground long-life small prismatic HTGR was carried out to obtain the conditions for successful decay heat removal by radiation and conduction inside the reactor building, and by radiation and natural cooling by air at the outer surface of the reactor building. Sensitivity analysis of the peak temperatures of both the core and the reactor building after reactor shutdown was performed by changing the physical characteristics of the reactor regions. Enlarging the reactor building was found to be an effective way to reduce the peak reactor building temperature to within its design limit. By using the obtained condition for design parameters, the appropriate sizes of reactor core and reactor building were evaluated for some reactors. Consequently, criticality and burnup analyses for the proposed reactors were performed to confirm the possibility of designing a long-life core for the core size and reactor power which meet the condition of removing decay heat successfully. Using our design, all the reactors with 20 wt% uranium enrichment could be critical for over nine years.

Open-access reader

About this research paper

What this paper is about

The design of a small high-temperature gas-cooled reactor (HTGR) for passive decay heat removal which could be located deeply underground was proposed previously. In the present work, analogue design analyses of passive decay heat removal for an above-ground long-life small prismatic HTGR was carried out to obtain the conditions for successful decay heat removal by radiation and conduction inside the reactor building, and by radiation and natural cooling by air at the outer surface of the reactor building. Sensitivity analysis of the peak temperatures of both the core and the reactor building after reactor shutdown was performed by changing the physical characteristics of the reactor regions. Enlarging the reactor building was found to be an effective way to reduce the peak reactor building temperature to within its design limit. By using the obtained condition for design parameters, the appropriate sizes of reactor core and reactor building were evaluated for some reactors. Consequently, criticality and burnup analyses for the proposed reactors were performed to confirm the possibility of designing a long-life core for the core size and reactor power which meet the condition of removing decay heat successfully. Using our design, all the reactors with 20 wt% uranium enrichment could be critical for over nine years.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The design of a small high-temperature gas-cooled reactor (HTGR) for passive decay heat removal which could be located deeply underground was proposed previously. In the present work, analogue design analyses of passive decay heat removal for an above-ground long-life small prismatic HTGR was carried out to obtain the conditions for successful decay heat removal by radiation and conduction inside the reactor building, and by radiation and natural cooling by air at the outer surface of the reactor building. Sensitivity analysis of the peak temperatures of both the core and the reactor building after reactor shutdown was performed by changing the physical characteristics of the reactor regions. Enlarging the reactor building was found to be an effective way to reduce the peak reactor building temperature to within its design limit. By using the obtained condition for design parameters, the appropriate sizes of reactor core and reactor building were evaluated for some reactors. Consequently, criticality and burnup analyses for the proposed reactors were performed to confirm the possibility of designing a long-life core for the core size and reactor power which meet the condition of removing decay heat successfully. Using our design, all the reactors with 20 wt% uranium enrichment could be critical for over nine years.

Key concepts: Decay heat, Nuclear engineering, Nuclear reactor core, Shutdown, Criticality, Natural circulation, Nuclear reactor, Reactor pressure vessel

Related papers

Back to paper searchBrowse research topicsOriginal source
Above-ground HTGR design for passive decay heat removal — Research Paper | ScholarLens