2015Frontiers in MicrobiologyOpen access

Development of a bacterial bioassay for atrazine and cyanuric acid detection

Anna Hua, Hervé Gueuné, Mickaël Cregut, Gérald Thouand, Marie-José Durand

Open full text 28 citations

Abstract

The s-triazine herbicides are compounds which can disseminate into soils and water. Due to their toxic effects on living organisms, their concentrations in drinking water are legislated by WHO recommendations. Here we have developed for the first time, to the best of our knowledge, an alternative method for physicochemical quantification using two bioluminescent bacterial biosensors: E. coli SM003 for cyanuric acid detection and E. coli SM004 for both atrazine and cyanuric acid detection. The concentration of cyanuric acid detection for E. coli SM003 ranges from 7.83 μM to 2.89 mM, and for E. coli SM004 ranges from 0.22 to 15 μM. Moreover, atrazine detection by E. coli SM004 ranges from 1.08 to 15 μM. According to WHO recommendations, the cyanuric acid detection range is sensitive enough to discriminate between polluted and drinking water. Nevertheless, the detection of atrazine by E. coli SM004 is only applicable for high concentrations of contaminants.

Open-access reader

About this research paper

What this paper is about

The s-triazine herbicides are compounds which can disseminate into soils and water. Due to their toxic effects on living organisms, their concentrations in drinking water are legislated by WHO recommendations. Here we have developed for the first time, to the best of our knowledge, an alternative method for physicochemical quantification using two bioluminescent bacterial biosensors: E. coli SM003 for cyanuric acid detection and E. coli SM004 for both atrazine and cyanuric acid detection. The concentration of cyanuric acid detection for E. coli SM003 ranges from 7.83 μM to 2.89 mM, and for E. coli SM004 ranges from 0.22 to 15 μM. Moreover, atrazine detection by E. coli SM004 ranges from 1.08 to 15 μM. According to WHO recommendations, the cyanuric acid detection range is sensitive enough to discriminate between polluted and drinking water. Nevertheless, the detection of atrazine by E. coli SM004 is only applicable for high concentrations of contaminants.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The s-triazine herbicides are compounds which can disseminate into soils and water. Due to their toxic effects on living organisms, their concentrations in drinking water are legislated by WHO recommendations. Here we have developed for the first time, to the best of our knowledge, an alternative method for physicochemical quantification using two bioluminescent bacterial biosensors: E. coli SM003 for cyanuric acid detection and E. coli SM004 for both atrazine and cyanuric acid detection. The concentration of cyanuric acid detection for E. coli SM003 ranges from 7.83 μM to 2.89 mM, and for E. coli SM004 ranges from 0.22 to 15 μM. Moreover, atrazine detection by E. coli SM004 ranges from 1.08 to 15 μM. According to WHO recommendations, the cyanuric acid detection range is sensitive enough to discriminate between polluted and drinking water. Nevertheless, the detection of atrazine by E. coli SM004 is only applicable for high concentrations of contaminants.

Key concepts: Cyanuric acid, Atrazine, Environmental chemistry, Bioreporter, Chemistry, Simazine, Bioassay, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of a bacterial bioassay for atrazine and cyanuric acid detection — Research Paper | ScholarLens