Development of operator independent bone cement vacuum mixing system for joint replacement surgery

Nicholas Dunne, Yuchun Xu, C. Daly, Jonathan E. Makem, Gavin Walker, J. F. Orr

Open publisher page 6 citations

Abstract

Acrylic bone cement is weakened by its porosity, which promotes the formation of microcracks, which contribute to major crack propagation and ultimately failure of the cement mantle. Bone cement mixing techniques play a significant role in determining the quality of bone cement produced. A high degree of porosity is found to exist in cement that is inadequately mixed. Current commercial bone cement mixing systems allow for the preparation of the bone cement under the application of a vacuum in a closed, sealed chamber by means of a repeatable mixing action. These mixing systems are perceived to be repeatable and reliable by orthopaedic community. In this paper, the quality of bone cement mixed using an operator independent bone cement mixing system was compared with that of cement prepared using commercially available devices. The results of the investigation highlighted that cement prepared using the automated, repeatable mixing regime that is operator independent demonstrated consistently better physical and mechanical properties in comparison with cement mixed using proprietary cement mixing devices. Furthermore, Design of Experiments software established the optimal factors that influenced the physical and mechanical properties of PMMA bone cement.

About this research paper

What this paper is about

Acrylic bone cement is weakened by its porosity, which promotes the formation of microcracks, which contribute to major crack propagation and ultimately failure of the cement mantle. Bone cement mixing techniques play a significant role in determining the quality of bone cement produced. A high degree of porosity is found to exist in cement that is inadequately mixed. Current commercial bone cement mixing systems allow for the preparation of the bone cement under the application of a vacuum in a closed, sealed chamber by means of a repeatable mixing action. These mixing systems are perceived to be repeatable and reliable by orthopaedic community. In this paper, the quality of bone cement mixed using an operator independent bone cement mixing system was compared with that of cement prepared using commercially available devices. The results of the investigation highlighted that cement prepared using the automated, repeatable mixing regime that is operator independent demonstrated consistently better physical and mechanical properties in comparison with cement mixed using proprietary cement mixing devices. Furthermore, Design of Experiments software established the optimal factors that influenced the physical and mechanical properties of PMMA bone cement.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Acrylic bone cement is weakened by its porosity, which promotes the formation of microcracks, which contribute to major crack propagation and ultimately failure of the cement mantle. Bone cement mixing techniques play a significant role in determining the quality of bone cement produced. A high degree of porosity is found to exist in cement that is inadequately mixed. Current commercial bone cement mixing systems allow for the preparation of the bone cement under the application of a vacuum in a closed, sealed chamber by means of a repeatable mixing action. These mixing systems are perceived to be repeatable and reliable by orthopaedic community. In this paper, the quality of bone cement mixed using an operator independent bone cement mixing system was compared with that of cement prepared using commercially available devices. The results of the investigation highlighted that cement prepared using the automated, repeatable mixing regime that is operator independent demonstrated consistently better physical and mechanical properties in comparison with cement mixed using proprietary cement mixing devices. Furthermore, Design of Experiments software established the optimal factors that influenced the physical and mechanical properties of PMMA bone cement.

Key concepts: Cement, Bone cement, Materials science, Mixing (physics), Porosity, Composite material, Physics, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of operator independent bone cement vacuum mixing system for joint replacement surgery — Research Paper | ScholarLens