High-speed microemulsion electrokinetic chromatography

Pierre‐Etienne Mahuzier, Brian J. Clark, Simon M. Bryant, Kevin D. Altria

Open publisher page 43 citations

Abstract

In previous reports of microemulsion electrokinetic chromatography (MEEKC), analysis times were typically in the order of 10 min as high-ionic strength buffers were used. These buffers produced high currents which limit the voltages which can be applied, therefore, analysis times could not be reduced. The primary cause of the high-ionic strength is the relatively high concentrations of surfactants required to form the microemulsion. The surfactant concentration can be lower when using an oil with a smaller surface tension. This preliminary study showed that migration times in MEEKC can be reduced to below 1 min by using a combination of an optimum microemulsion composition, high voltage, high temperature, short capillaries by injecting via the "short end", or by simultaneously applying pressure and voltage. Long injection sequences and quantitation were found to be possible with minimum buffer depletion effects.

About this research paper

What this paper is about

In previous reports of microemulsion electrokinetic chromatography (MEEKC), analysis times were typically in the order of 10 min as high-ionic strength buffers were used. These buffers produced high currents which limit the voltages which can be applied, therefore, analysis times could not be reduced. The primary cause of the high-ionic strength is the relatively high concentrations of surfactants required to form the microemulsion. The surfactant concentration can be lower when using an oil with a smaller surface tension. This preliminary study showed that migration times in MEEKC can be reduced to below 1 min by using a combination of an optimum microemulsion composition, high voltage, high temperature, short capillaries by injecting via the "short end", or by simultaneously applying pressure and voltage. Long injection sequences and quantitation were found to be possible with minimum buffer depletion effects.

Why it matters

OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In previous reports of microemulsion electrokinetic chromatography (MEEKC), analysis times were typically in the order of 10 min as high-ionic strength buffers were used. These buffers produced high currents which limit the voltages which can be applied, therefore, analysis times could not be reduced. The primary cause of the high-ionic strength is the relatively high concentrations of surfactants required to form the microemulsion. The surfactant concentration can be lower when using an oil with a smaller surface tension. This preliminary study showed that migration times in MEEKC can be reduced to below 1 min by using a combination of an optimum microemulsion composition, high voltage, high temperature, short capillaries by injecting via the "short end", or by simultaneously applying pressure and voltage. Long injection sequences and quantitation were found to be possible with minimum buffer depletion effects.

Key concepts: Electrokinetic phenomena, Microemulsion, Chromatography, Micellar electrokinetic chromatography, Chemistry, Electrophoresis, Pulmonary surfactant, Biochemistry