2014Bulletin of the Chemical Society of EthiopiaOpen access

Trace determination of bisphenol-A in landfill leachate samples by dispersive liquid- liquid microextraction followed by high performance liquid chromatography

Nader Bahramifar, Reyhaneh Rahnama, S. Saberimoghaddam

Open full text 16 citations

Abstract

A simple, rapid and efficient sample pretreatment technique, termed dispersive liquid-liquid microextraction (DLLME), was developed as an extraction methodology to determine bisphenol-A (BPA), in landfill leachate samples prior to high performance liquid chromatography (HPLC)-ultraviolet detection. Some effective parameters, such as pH, extraction and disperser solvent type and their volumes, time of extraction and salt effect have been optimized using the one-factor-at-a-time approach. Under the optimum conditions, the preconcentration factor 25 was obtained from only 5 mL of the sample. The calibration graph was linear in the range of 5-500 µg L-1 with the detection limit of 1.5 µg L-1. The relative standard deviation (RSD) for ten replicate measurements of 20 µg L-1 of BPA was 2.5%. Finally, the method was successfully applied for the extraction and determination of BPA in some landfill leachate samples with a relative recovery of 98–109% and RSD less than 5%. KEY WORDS: Dispersive liquid-liquid microextraction, Bisphenol-A, Landfill leachate samples, High-performance liquid chromatography Bull. Chem. Soc. Ethiop. 2014, 28(3), 329-338.DOI: http://dx.doi.org/10.4314/bcse.v28i3.2

About this research paper

What this paper is about

A simple, rapid and efficient sample pretreatment technique, termed dispersive liquid-liquid microextraction (DLLME), was developed as an extraction methodology to determine bisphenol-A (BPA), in landfill leachate samples prior to high performance liquid chromatography (HPLC)-ultraviolet detection. Some effective parameters, such as pH, extraction and disperser solvent type and their volumes, time of extraction and salt effect have been optimized using the one-factor-at-a-time approach. Under the optimum conditions, the preconcentration factor 25 was obtained from only 5 mL of the sample. The calibration graph was linear in the range of 5-500 µg L-1 with the detection limit of 1.5 µg L-1. The relative standard deviation (RSD) for ten replicate measurements of 20 µg L-1 of BPA was 2.5%. Finally, the method was successfully applied for the extraction and determination of BPA in some landfill leachate samples with a relative recovery of 98–109% and RSD less than 5%. KEY WORDS: Dispersive liquid-liquid microextraction, Bisphenol-A, Landfill leachate samples, High-performance liquid chromatography Bull. Chem. Soc. Ethiop. 2014, 28(3), 329-338.DOI: http://dx.doi.org/10.4314/bcse.v28i3.2

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, rapid and efficient sample pretreatment technique, termed dispersive liquid-liquid microextraction (DLLME), was developed as an extraction methodology to determine bisphenol-A (BPA), in landfill leachate samples prior to high performance liquid chromatography (HPLC)-ultraviolet detection. Some effective parameters, such as pH, extraction and disperser solvent type and their volumes, time of extraction and salt effect have been optimized using the one-factor-at-a-time approach. Under the optimum conditions, the preconcentration factor 25 was obtained from only 5 mL of the sample. The calibration graph was linear in the range of 5-500 µg L-1 with the detection limit of 1.5 µg L-1. The relative standard deviation (RSD) for ten replicate measurements of 20 µg L-1 of BPA was 2.5%. Finally, the method was successfully applied for the extraction and determination of BPA in some landfill leachate samples with a relative recovery of 98–109% and RSD less than 5%. KEY WORDS: Dispersive liquid-liquid microextraction, Bisphenol-A, Landfill leachate samples, High-performance liquid chromatography Bull. Chem. Soc. Ethiop. 2014, 28(3), 329-338.DOI: http://dx.doi.org/10.4314/bcse.v28i3.2

Key concepts: Chemistry, Chromatography, Extraction (chemistry), Detection limit, High-performance liquid chromatography, Leachate, Disperser, Enrichment factor

Related papers

Back to paper searchBrowse research topicsOriginal source
Trace determination of bisphenol-A in landfill leachate samples by dispersive liquid- liquid microextraction followed by high performance liquid chromatography — Research Paper | ScholarLens