1965AnesthesiologyRequires access

Mechanics of Breathing During Anesthesia. 2. The Influence of Airway Adequacy

Martin I. Gold, Martin Helrich

Open publisher page 7 citations

Abstract

Pulmonary compliance (CL) and resistance (RL) were measured simultaneously in 13 supine patients prior to operation in both awake and anesthetized states. During anesthesia three air-way situations were compared: (1) mask, no airway, (2) mask, oral airway, and (3) endotracheal airway. During mask anesthesia RL. was 123 per cent above the control without oral airway, 55 per cent above the control with oral airway, and with tracheal intubation RL decreased to 18 per cent below the control. During periods of increased RL with mask, such “subtle” obstruction was clinically undetectable, not accompanied by decreased tidal exchange. The primary reason for elevated RL during mask anesthesia was due to increases in upper airway resistances. Compliance fell approximately 15 per cent during anesthesia, remained at a depressed level and was uninfluenced by the type of airway or its adequacy.

About this research paper

What this paper is about

Pulmonary compliance (CL) and resistance (RL) were measured simultaneously in 13 supine patients prior to operation in both awake and anesthetized states. During anesthesia three air-way situations were compared: (1) mask, no airway, (2) mask, oral airway, and (3) endotracheal airway. During mask anesthesia RL. was 123 per cent above the control without oral airway, 55 per cent above the control with oral airway, and with tracheal intubation RL decreased to 18 per cent below the control. During periods of increased RL with mask, such “subtle” obstruction was clinically undetectable, not accompanied by decreased tidal exchange. The primary reason for elevated RL during mask anesthesia was due to increases in upper airway resistances. Compliance fell approximately 15 per cent during anesthesia, remained at a depressed level and was uninfluenced by the type of airway or its adequacy.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pulmonary compliance (CL) and resistance (RL) were measured simultaneously in 13 supine patients prior to operation in both awake and anesthetized states. During anesthesia three air-way situations were compared: (1) mask, no airway, (2) mask, oral airway, and (3) endotracheal airway. During mask anesthesia RL. was 123 per cent above the control without oral airway, 55 per cent above the control with oral airway, and with tracheal intubation RL decreased to 18 per cent below the control. During periods of increased RL with mask, such “subtle” obstruction was clinically undetectable, not accompanied by decreased tidal exchange. The primary reason for elevated RL during mask anesthesia was due to increases in upper airway resistances. Compliance fell approximately 15 per cent during anesthesia, remained at a depressed level and was uninfluenced by the type of airway or its adequacy.

Key concepts: Medicine, Anesthesia, Airway, Breathing, Respiratory physiology, Respiratory system, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Mechanics of Breathing During Anesthesia. 2. The Influence of Airway Adequacy — Research Paper | ScholarLens