1979Acta Anaesthesiologica ScandinavicaRequires access

Patient Controlled Analgesic Therapy in the Early Postoperative Period

A. Tamsen, P. Hartvig, Bengt Dahlström, B. Lindström, M. Hson Holmdahl

Open publisher page 82 citations

Abstract

Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia and the postoperative self-administration period, and the concentrations of pethidine and nor-pethidine were determined. Separate single-dose studies in eight patients yielded pharmacokinetic parameters which made possible computer simulations of continuous plasma concentration curves for the anaesthesia and postoperative self-administration period. The consumption of pethidine showed great interindividual variations with a mean consumption for the entire group of 26 mg per hour. The patients established steady-state plasma concentrations with far less than the maximum amount of pethidine allowed. The mean measured plasma concentration of pethidine which provided adequate analgesia was 738 +/- 149 ng/ml. Simulated and measured plasma concentrations were in close agreement. The individual mean drug consumption per hour during self-administration correlated closely with the individual elimination rate of pethidine. No serious side effects were observed. Thus, patient-controlled analgesic therapy offers an individualized analgesic supply to meet an analgesic demand which is governed by each patient's appreciation of pain.

About this research paper

What this paper is about

Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia and the postoperative self-administration period, and the concentrations of pethidine and nor-pethidine were determined. Separate single-dose studies in eight patients yielded pharmacokinetic parameters which made possible computer simulations of continuous plasma concentration curves for the anaesthesia and postoperative self-administration period. The consumption of pethidine showed great interindividual variations with a mean consumption for the entire group of 26 mg per hour. The patients established steady-state plasma concentrations with far less than the maximum amount of pethidine allowed. The mean measured plasma concentration of pethidine which provided adequate analgesia was 738 +/- 149 ng/ml. Simulated and measured plasma concentrations were in close agreement. The individual mean drug consumption per hour during self-administration correlated closely with the individual elimination rate of pethidine. No serious side effects were observed. Thus, patient-controlled analgesic therapy offers an individualized analgesic supply to meet an analgesic demand which is governed by each patient's appreciation of pain.

Why it matters

OpenAlex reports 82 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia and the postoperative self-administration period, and the concentrations of pethidine and nor-pethidine were determined. Separate single-dose studies in eight patients yielded pharmacokinetic parameters which made possible computer simulations of continuous plasma concentration curves for the anaesthesia and postoperative self-administration period. The consumption of pethidine showed great interindividual variations with a mean consumption for the entire group of 26 mg per hour. The patients established steady-state plasma concentrations with far less than the maximum amount of pethidine allowed. The mean measured plasma concentration of pethidine which provided adequate analgesia was 738 +/- 149 ng/ml. Simulated and measured plasma concentrations were in close agreement. The individual mean drug consumption per hour during self-administration correlated closely with the individual elimination rate of pethidine. No serious side effects were observed. Thus, patient-controlled analgesic therapy offers an individualized analgesic supply to meet an analgesic demand which is governed by each patient's appreciation of pain.

Key concepts: Pethidine, Medicine, Analgesic, Anesthesia, Pharmacokinetics, Plasma concentration, Self-administration, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Patient Controlled Analgesic Therapy in the Early Postoperative Period — Research Paper | ScholarLens