2012•Journal of ChemistryOpen access

Validated RP‐HPLC Method for the Assay of Etoricoxib (A Non‐Steroidal Anti‐Inflammatory Drug) in Pharmaceutical Dosage Forms

Topalli Srinivasu, T.G. Chandrashekhar, Mukthinuthalapati Mathrusri Annapurna

Open full text 20 citations

Abstract

A simple, accurate, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for the quantitative determination of Etoricoxib in pharmaceutical dosage forms. The assay was performed on Hypersil ODS C‐18 (250 x 4.6 mm., 5µm particle size) column using acetonitrile and potassium dihydrogen phosphate buffer (pH 4.2) (46:54 % v/v) as mobile phase with UV detection at 280 nm (flow rate 1.2 ml/min). Bromhexine was used as an internal standard. Quantization was achieved by measurement of the peak area ratio of the drug to the internal standard. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.0704 µg ml-1 and 0.2134 µg ml-1 respectively. Each analysis required no longer than 10 minutes. The calibration curve was linear over the concentration range from 0.5‐85.0 µg ml-1. The retention times of Etoricoxib and Bromhexine were found to be 3.083 and 7.631 minutes respectively. The proposed method was validated according to the ICH guidelines and can be used successfully to analyse marketed formulations.

Open-access reader

About this research paper

What this paper is about

A simple, accurate, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for the quantitative determination of Etoricoxib in pharmaceutical dosage forms. The assay was performed on Hypersil ODS C‐18 (250 x 4.6 mm., 5µm particle size) column using acetonitrile and potassium dihydrogen phosphate buffer (pH 4.2) (46:54 % v/v) as mobile phase with UV detection at 280 nm (flow rate 1.2 ml/min). Bromhexine was used as an internal standard. Quantization was achieved by measurement of the peak area ratio of the drug to the internal standard. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.0704 µg ml-1 and 0.2134 µg ml-1 respectively. Each analysis required no longer than 10 minutes. The calibration curve was linear over the concentration range from 0.5‐85.0 µg ml-1. The retention times of Etoricoxib and Bromhexine were found to be 3.083 and 7.631 minutes respectively. The proposed method was validated according to the ICH guidelines and can be used successfully to analyse marketed formulations.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, accurate, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for the quantitative determination of Etoricoxib in pharmaceutical dosage forms. The assay was performed on Hypersil ODS C‐18 (250 x 4.6 mm., 5µm particle size) column using acetonitrile and potassium dihydrogen phosphate buffer (pH 4.2) (46:54 % v/v) as mobile phase with UV detection at 280 nm (flow rate 1.2 ml/min). Bromhexine was used as an internal standard. Quantization was achieved by measurement of the peak area ratio of the drug to the internal standard. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.0704 µg ml-1 and 0.2134 µg ml-1 respectively. Each analysis required no longer than 10 minutes. The calibration curve was linear over the concentration range from 0.5‐85.0 µg ml-1. The retention times of Etoricoxib and Bromhexine were found to be 3.083 and 7.631 minutes respectively. The proposed method was validated according to the ICH guidelines and can be used successfully to analyse marketed formulations.

Key concepts: Etoricoxib, Chromatography, Detection limit, Chemistry, Calibration curve, Dosage form, Particle size, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Validated RP‐HPLC Method for the Assay of Etoricoxib (A Non‐Steroidal Anti‐Inflammatory Drug) in Pharmaceutical Dosage Forms — Research Paper | ScholarLens