Accuracy of twenty-four-hour ambulatory blood pressure monitoring (night???day values) for the diagnosis of secondary hypertension
Henrique Barros
Abstract
Henrique Barros
Abstract
OBJECTIVES: To determine the accuracy of 24-h ambulatory blood pressure monitoring, using the relationship between night-time and daytime values, in diagnosing secondary hypertension. PATIENTS AND METHODS: A prospective study was performed in a referred population of 402 hypertensive patients (clinic systolic/diastolic blood pressure > 140/90 mmHg). The ambulatory monitoring data included 24-h mean, awake (daytime) and sleeping (night-time) values. Secondary hypertension was diagnosed by standard procedures. To describe the accuracy of ambulatory blood pressure monitoring, receiver-operator characteristic curves were constructed, using sensitivity and specificity values for deciles of the distribution of overnight blood pressure falls (absolute and percentage). Measurements included the fall in nocturnal blood pressure, sensitivity (the percentage of those with secondary hypertension who were classified as non-dippers), specificity (the percentage of non-secondary hypertensives who were classified as dippers) and predictive values of ambulatory blood pressure monitoring. RESULTS: On average, overnight systolic/diastolic blood pressure fell in primary hypertensives (n = 290) by 20/18 mmHg (13%/19%), in white-coat hypertensives (n = 65, daytime ambulatory blood pressure <135/87 mmHg) by 17/15 mmHg (13%/19%) and in patients with secondary hypertension (n = 47, renal/renovascular and endocrine forms) by 13/11 mmHg (9%/12%). From receiver-operator characteristic curves, the nocturnal blood pressure fall of 15 mmHg showed the highest accuracy, with a sensitivity/specificity of 61%/69% (systolic) and 75%/62% (diastolic) whereas 10% (systolic) and 15% (diastolic) nocturnal falls had a sensitivity/specificity of 62%/74% (systolic) and 62%/70% (diastolic). The ambulatory blood pressure data had a high (>93%) negative predictive value for secondary hypertension. CONCLUSIONS: Secondary hypertension is associated with a blunted nocturnal fall in blood pressure. Ambulatory blood pressure monitoring data are not critically important for the diagnosis and screening of secondary hypertension but may be helpful in excluding it.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVES: To determine the accuracy of 24-h ambulatory blood pressure monitoring, using the relationship between night-time and daytime values, in diagnosing secondary hypertension. PATIENTS AND METHODS: A prospective study was performed in a referred population of 402 hypertensive patients (clinic systolic/diastolic blood pressure > 140/90 mmHg). The ambulatory monitoring data included 24-h mean, awake (daytime) and sleeping (night-time) values. Secondary hypertension was diagnosed by standard procedures. To describe the accuracy of ambulatory blood pressure monitoring, receiver-operator characteristic curves were constructed, using sensitivity and specificity values for deciles of the distribution of overnight blood pressure falls (absolute and percentage). Measurements included the fall in nocturnal blood pressure, sensitivity (the percentage of those with secondary hypertension who were classified as non-dippers), specificity (the percentage of non-secondary hypertensives who were classified as dippers) and predictive values of ambulatory blood pressure monitoring. RESULTS: On average, overnight systolic/diastolic blood pressure fell in primary hypertensives (n = 290) by 20/18 mmHg (13%/19%), in white-coat hypertensives (n = 65, daytime ambulatory blood pressure <135/87 mmHg) by 17/15 mmHg (13%/19%) and in patients with secondary hypertension (n = 47, renal/renovascular and endocrine forms) by 13/11 mmHg (9%/12%). From receiver-operator characteristic curves, the nocturnal blood pressure fall of 15 mmHg showed the highest accuracy, with a sensitivity/specificity of 61%/69% (systolic) and 75%/62% (diastolic) whereas 10% (systolic) and 15% (diastolic) nocturnal falls had a sensitivity/specificity of 62%/74% (systolic) and 62%/70% (diastolic). The ambulatory blood pressure data had a high (>93%) negative predictive value for secondary hypertension. CONCLUSIONS: Secondary hypertension is associated with a blunted nocturnal fall in blood pressure. Ambulatory blood pressure monitoring data are not critically important for the diagnosis and screening of secondary hypertension but may be helpful in excluding it.
Key concepts: Medicine, Ambulatory blood pressure, Ambulatory, Blood pressure, Emergency medicine, Pediatrics, Internal medicine