2001Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)Open access

Clean-up Procedure with Ion-exchange Mini Column in the Analysis of Flusulfamide in Agricultural Products by HPLC.

Yumiko Nakamura, SUSUMU ISHIMITSU, Yukari Tsumura, Kimihiko Yoshii, Akiko Kaihara, Yasuhide TONOGAI

Open full text 0 citations

Abstract

A clean-up procedure with an ion-exchange column in the analysis of flusulfamide by HPLC was examined. Pesticide in the sample was extracted with methanol following liquid-liquid partition with ethyl acetate. The ethyl acetate fraction was cleaned up with silica gel column chromatography. The eluate from the silica gel column was further cleaned up with SAX + PSA mini column, then determined by HPLC. Carotenoids and interfering peaks were removed by washing the combined mini columns with 10 mL of 20% acetone-containing n-hexane and 5 mL of acetone, and flusulfamide was eluted with 35 mL of acetone.

Open-access reader

About this research paper

What this paper is about

A clean-up procedure with an ion-exchange column in the analysis of flusulfamide by HPLC was examined. Pesticide in the sample was extracted with methanol following liquid-liquid partition with ethyl acetate. The ethyl acetate fraction was cleaned up with silica gel column chromatography. The eluate from the silica gel column was further cleaned up with SAX + PSA mini column, then determined by HPLC. Carotenoids and interfering peaks were removed by washing the combined mini columns with 10 mL of 20% acetone-containing n-hexane and 5 mL of acetone, and flusulfamide was eluted with 35 mL of acetone.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A clean-up procedure with an ion-exchange column in the analysis of flusulfamide by HPLC was examined. Pesticide in the sample was extracted with methanol following liquid-liquid partition with ethyl acetate. The ethyl acetate fraction was cleaned up with silica gel column chromatography. The eluate from the silica gel column was further cleaned up with SAX + PSA mini column, then determined by HPLC. Carotenoids and interfering peaks were removed by washing the combined mini columns with 10 mL of 20% acetone-containing n-hexane and 5 mL of acetone, and flusulfamide was eluted with 35 mL of acetone.

Key concepts: Chromatography, Column (typography), High-performance liquid chromatography, Chemistry, Ion exchange, Ion, Computer science, Organic chemistry