RP‐HPLC Method for the Determination of Tenofovir in Pharmaceutical Formulations and Spiked Human Plasma
P.B. Kandagal, D.H. Manjunatha, J. Seetharamappa, Shankara S. Kalanur
Abstract
P.B. Kandagal, D.H. Manjunatha, J. Seetharamappa, Shankara S. Kalanur
Abstract
A simple reverse‐phase high‐performance liquid chromatographic method for the determination of tenofovir disoproxil fumarate (TDF) in pharmaceutical formulations and human plasma samples has been developed and validated. Piroxicam (PRX) was used as an internal standard. The assay of the drug was performed on a CLC C18 (5 μ, 25 cm×4.6 mm i.d.) with UV detection at 259 nm. The mobile phase consisted of acetonitrile–water mixture in the ratio of 75∶25, and a flow rate of 1 ml/min was maintained. The standard curve was linear over the range of 0.2–10 µg/ml (r 2=0.9966). Analytic parameters have been evaluated. Within‐day and between‐day precision as expressed by relative standard deviation was found to be less than 2%. The method has been applied successfully for the determination of TDF in spiked human plasma samples and pharmaceutical formulations.
OpenAlex reports 60 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple reverse‐phase high‐performance liquid chromatographic method for the determination of tenofovir disoproxil fumarate (TDF) in pharmaceutical formulations and human plasma samples has been developed and validated. Piroxicam (PRX) was used as an internal standard. The assay of the drug was performed on a CLC C18 (5 μ, 25 cm×4.6 mm i.d.) with UV detection at 259 nm. The mobile phase consisted of acetonitrile–water mixture in the ratio of 75∶25, and a flow rate of 1 ml/min was maintained. The standard curve was linear over the range of 0.2–10 µg/ml (r 2=0.9966). Analytic parameters have been evaluated. Within‐day and between‐day precision as expressed by relative standard deviation was found to be less than 2%. The method has been applied successfully for the determination of TDF in spiked human plasma samples and pharmaceutical formulations.
Key concepts: Chemistry, Chromatography, Human plasma, Tenofovir, High-performance liquid chromatography, Bioanalysis, Human immunodeficiency virus (HIV), Virology