1999Journal of Cataract & Refractive SurgeryRequires access

Ciliary body detachment caused by capsule contraction1

Ines Lanzl, C BONYTHON KOPP

Open publisher page 25 citations

Abstract

A 74-year-old woman developed capsule contraction associated with hypotony and choroidal effusion 18 months after uneventful phacoemulsification with 3-piece poly(methyl methacrylate) intraocular lens implantation. Ultrasound biomicroscopy revealed ciliary body detachment and stretched zonules. A radial neodymium: YAG anterior capsulotomy was performed, resulting in the resolution of the ciliary body detachment and choroidal effusion as well as in normal intraocular pressure over 4 days.

About this research paper

What this paper is about

A 74-year-old woman developed capsule contraction associated with hypotony and choroidal effusion 18 months after uneventful phacoemulsification with 3-piece poly(methyl methacrylate) intraocular lens implantation. Ultrasound biomicroscopy revealed ciliary body detachment and stretched zonules. A radial neodymium: YAG anterior capsulotomy was performed, resulting in the resolution of the ciliary body detachment and choroidal effusion as well as in normal intraocular pressure over 4 days.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A 74-year-old woman developed capsule contraction associated with hypotony and choroidal effusion 18 months after uneventful phacoemulsification with 3-piece poly(methyl methacrylate) intraocular lens implantation. Ultrasound biomicroscopy revealed ciliary body detachment and stretched zonules. A radial neodymium: YAG anterior capsulotomy was performed, resulting in the resolution of the ciliary body detachment and choroidal effusion as well as in normal intraocular pressure over 4 days.

Key concepts: Ultrasound biomicroscopy, Phacoemulsification, Ciliary body, Ophthalmology, Medicine, Intraocular lens, Intraocular pressure, Capsulotomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Ciliary body detachment caused by capsule contraction1 — Research Paper | ScholarLens