2011EurosurveillanceOpen access

A multiplex one-step real-time RT-PCR assay for influenza surveillance

Ingrid Huber, Hartmut Campe, Daniela Sebah, Christine Hartberger, Р. Конрад, M. Bayer, Ulrich Busch, Andreas Sing

Open full text 24 citations

Abstract

For surveillance purposes real-time PCR assays for influenza viruses had to be adapted to the pandemic influenza A(H1N1)2009 strain. We combined published primers and probes for influenza A, influenza B and an internal amplification control with a detection system for influenza A(H1N1)2009 to set up a rapid, reliable, simple and cost-effective high-throughput multiplex one-step real-time RT-PCR. The workflow also includes automated sample preparation for high-throughput screening. The lower limit of detection of the multiplex assay was 3.5x10(2) RNA copies per PCR reaction. The diagnostic sensitivity of the multiplex assay was 87.7%, but increased to 99.4% for influenza-positive samples yielding C(t) values of less than 34 cycles in the respective diagnostic assay. High specificity was confirmed by sequencing and correct detection of 15 reference samples from two quality assurance studies. The multiplex PCR was introduced for surveillance of samples from a network of general practitioners and paediatricians in Bavaria, Germany during the influenza pandemic of 2009. Comparison with surveillance data from reported cases proved the reliability of the multiplex assay for influenza surveillance programmes.

Open-access reader

About this research paper

What this paper is about

For surveillance purposes real-time PCR assays for influenza viruses had to be adapted to the pandemic influenza A(H1N1)2009 strain. We combined published primers and probes for influenza A, influenza B and an internal amplification control with a detection system for influenza A(H1N1)2009 to set up a rapid, reliable, simple and cost-effective high-throughput multiplex one-step real-time RT-PCR. The workflow also includes automated sample preparation for high-throughput screening. The lower limit of detection of the multiplex assay was 3.5x10(2) RNA copies per PCR reaction. The diagnostic sensitivity of the multiplex assay was 87.7%, but increased to 99.4% for influenza-positive samples yielding C(t) values of less than 34 cycles in the respective diagnostic assay. High specificity was confirmed by sequencing and correct detection of 15 reference samples from two quality assurance studies. The multiplex PCR was introduced for surveillance of samples from a network of general practitioners and paediatricians in Bavaria, Germany during the influenza pandemic of 2009. Comparison with surveillance data from reported cases proved the reliability of the multiplex assay for influenza surveillance programmes.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For surveillance purposes real-time PCR assays for influenza viruses had to be adapted to the pandemic influenza A(H1N1)2009 strain. We combined published primers and probes for influenza A, influenza B and an internal amplification control with a detection system for influenza A(H1N1)2009 to set up a rapid, reliable, simple and cost-effective high-throughput multiplex one-step real-time RT-PCR. The workflow also includes automated sample preparation for high-throughput screening. The lower limit of detection of the multiplex assay was 3.5x10(2) RNA copies per PCR reaction. The diagnostic sensitivity of the multiplex assay was 87.7%, but increased to 99.4% for influenza-positive samples yielding C(t) values of less than 34 cycles in the respective diagnostic assay. High specificity was confirmed by sequencing and correct detection of 15 reference samples from two quality assurance studies. The multiplex PCR was introduced for surveillance of samples from a network of general practitioners and paediatricians in Bavaria, Germany during the influenza pandemic of 2009. Comparison with surveillance data from reported cases proved the reliability of the multiplex assay for influenza surveillance programmes.

Key concepts: Multiplex, Real-time polymerase chain reaction, Virology, Medicine, Multiplex polymerase chain reaction, Polymerase chain reaction, Biology, Bioinformatics

Related papers

Back to paper searchBrowse research topicsOriginal source
A multiplex one-step real-time RT-PCR assay for influenza surveillance — Research Paper | ScholarLens