1953Electrical EngineeringRequires access

Pneumatic mechanisms for power circuit breakers

R. C. Van Sickle, William T. Parker, F. E. Florschutz

Open publisher page 0 citations

Abstract

PNEUMATIC OPERATION of power circuit breakers, which started before 1900, was used very little until the last decade. The increasing energy required for closing circuit breakers of higher and higher rating, and the demand for quicker closing and reclosing, enhanced the advantages of the pneumatic mechanism and led to its present predominance in the operation of large power circuit breakers. Experience gained with the mechanisms which pioneered the applications and gained widespread use have guided the development of a new line of devices to meet modern requirements of circuit breakers over the voltage range of 230 to 14.4 kv, interrupting capacity range from the highest down to 500 megavolt-amperes, and interrupting times of 8, 5, and 3 cycles.

About this research paper

What this paper is about

PNEUMATIC OPERATION of power circuit breakers, which started before 1900, was used very little until the last decade. The increasing energy required for closing circuit breakers of higher and higher rating, and the demand for quicker closing and reclosing, enhanced the advantages of the pneumatic mechanism and led to its present predominance in the operation of large power circuit breakers. Experience gained with the mechanisms which pioneered the applications and gained widespread use have guided the development of a new line of devices to meet modern requirements of circuit breakers over the voltage range of 230 to 14.4 kv, interrupting capacity range from the highest down to 500 megavolt-amperes, and interrupting times of 8, 5, and 3 cycles.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PNEUMATIC OPERATION of power circuit breakers, which started before 1900, was used very little until the last decade. The increasing energy required for closing circuit breakers of higher and higher rating, and the demand for quicker closing and reclosing, enhanced the advantages of the pneumatic mechanism and led to its present predominance in the operation of large power circuit breakers. Experience gained with the mechanisms which pioneered the applications and gained widespread use have guided the development of a new line of devices to meet modern requirements of circuit breakers over the voltage range of 230 to 14.4 kv, interrupting capacity range from the highest down to 500 megavolt-amperes, and interrupting times of 8, 5, and 3 cycles.

Key concepts: Circuit breaker, Distribution board, Electrical engineering, Sulfur hexafluoride circuit breaker, Prospective short circuit current, Closing (real estate), Fuse (electrical), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Pneumatic mechanisms for power circuit breakers — Research Paper | ScholarLens