1991The Thoracic and Cardiovascular SurgeonRequires access

Factors Determining Ventricular Fibrillation after Induced Cardiac Arrest

G. Görlach, T. Podzuweit, B. Borsutzky, Eike Lohmann, F. Dapper

Open publisher page 7 citations

Abstract

Ventricular fibrillation following release of the aortic cross clamp is not uncommon. In 38 patients undergoing aortic valve replacement we investigated if this disturbance of rhythm is due to perioperative myocardial ischemia or due to deterioration of myocardial function prior to surgery. In all cases hypothermic cardioplegic arrest (Bretschneider) was used. The mean duration of ischemia was 49.39 +/- 10.46 minutes. After release of the aortic cross clamp in 17 of 38 patients ventricular fibrillation occurred. To find out which factors are responsible for the occurrence of ventricular fibrillation we performed a statistical analysis. Thereby we found out that the occurrence of ventricular fibrillation did not correlate with ischemia, the maximal level of myocardium-bound creatine kinase, the NYHA stage, or the left ventricular end diastolic pressure. The left-ventricular concentration of noradrenaline determined just before release of the aortic cross clamp showed a significant negative correlation with the occurrence of ventricular fibrillation. From our results we conclude that ischemic injury was not the determining factor for the occurrence of ventricular fibrillation in our study. We suggest that the significant correlation with reduced myocardial noradrenaline content demonstrates that myocardial deterioration prior to surgery is the determining factor for the occurrence of ventricular fibrillation.

About this research paper

What this paper is about

Ventricular fibrillation following release of the aortic cross clamp is not uncommon. In 38 patients undergoing aortic valve replacement we investigated if this disturbance of rhythm is due to perioperative myocardial ischemia or due to deterioration of myocardial function prior to surgery. In all cases hypothermic cardioplegic arrest (Bretschneider) was used. The mean duration of ischemia was 49.39 +/- 10.46 minutes. After release of the aortic cross clamp in 17 of 38 patients ventricular fibrillation occurred. To find out which factors are responsible for the occurrence of ventricular fibrillation we performed a statistical analysis. Thereby we found out that the occurrence of ventricular fibrillation did not correlate with ischemia, the maximal level of myocardium-bound creatine kinase, the NYHA stage, or the left ventricular end diastolic pressure. The left-ventricular concentration of noradrenaline determined just before release of the aortic cross clamp showed a significant negative correlation with the occurrence of ventricular fibrillation. From our results we conclude that ischemic injury was not the determining factor for the occurrence of ventricular fibrillation in our study. We suggest that the significant correlation with reduced myocardial noradrenaline content demonstrates that myocardial deterioration prior to surgery is the determining factor for the occurrence of ventricular fibrillation.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Ventricular fibrillation following release of the aortic cross clamp is not uncommon. In 38 patients undergoing aortic valve replacement we investigated if this disturbance of rhythm is due to perioperative myocardial ischemia or due to deterioration of myocardial function prior to surgery. In all cases hypothermic cardioplegic arrest (Bretschneider) was used. The mean duration of ischemia was 49.39 +/- 10.46 minutes. After release of the aortic cross clamp in 17 of 38 patients ventricular fibrillation occurred. To find out which factors are responsible for the occurrence of ventricular fibrillation we performed a statistical analysis. Thereby we found out that the occurrence of ventricular fibrillation did not correlate with ischemia, the maximal level of myocardium-bound creatine kinase, the NYHA stage, or the left ventricular end diastolic pressure. The left-ventricular concentration of noradrenaline determined just before release of the aortic cross clamp showed a significant negative correlation with the occurrence of ventricular fibrillation. From our results we conclude that ischemic injury was not the determining factor for the occurrence of ventricular fibrillation in our study. We suggest that the significant correlation with reduced myocardial noradrenaline content demonstrates that myocardial deterioration prior to surgery is the determining factor for the occurrence of ventricular fibrillation.

Key concepts: Medicine, Ventricular fibrillation, Cardiology, Internal medicine, Aortic cross-clamp, Fibrillation, Ischemia, Diastole

Related papers

Back to paper searchBrowse research topicsOriginal source
Factors Determining Ventricular Fibrillation after Induced Cardiac Arrest — Research Paper | ScholarLens