2008Journal of Analytical Atomic SpectrometryRequires access

Determination of inorganic and total mercury by flow injection vapor generation atomic absorption spectrometry using a W-coil atomizer

Orkun Alp, Nusret Ertaş

Open publisher page 30 citations

Abstract

A tungsten coil (150 W, 15 V) was used as the atomizer for the proposed Flow Injection Vapor Generation Atomic Absorption Spectrometry (FI-VGAAS) system to determine inorganic mercury and total mercury concentrations. In the proposed method inorganic mercury was measured when the W-coil is at room temperature and total mercury was measured when the W-coil temperature was set to 500 °C. The organic mercury concentration was calculated by subtracting the inorganic mercury concentration from the total mercury concentration. The calibration graphs were linear up to 100 ng ml−1. Limit of detection (LOD) values for inorganic mercury and methyl mercury were 0.60 ng ml−1 and 0.89 ng ml−1 respectively. The precision of the method in terms of RSD was between 2–3%, and the sampling frequency was 100 h−1. In order to validate the proposed method, known concentrations of methyl mercury and inorganic mercury were spiked into deionized water and tap water samples. Certified reference materials (CRM) IAEA-085 and NRC DOLT-3 were analyzed after microwave assisted extraction with 6.0 mol l−1HCl solutions. Both inorganic mercury and methyl mercury concentrations were in agreement with the certified values.

About this research paper

What this paper is about

A tungsten coil (150 W, 15 V) was used as the atomizer for the proposed Flow Injection Vapor Generation Atomic Absorption Spectrometry (FI-VGAAS) system to determine inorganic mercury and total mercury concentrations. In the proposed method inorganic mercury was measured when the W-coil is at room temperature and total mercury was measured when the W-coil temperature was set to 500 °C. The organic mercury concentration was calculated by subtracting the inorganic mercury concentration from the total mercury concentration. The calibration graphs were linear up to 100 ng ml−1. Limit of detection (LOD) values for inorganic mercury and methyl mercury were 0.60 ng ml−1 and 0.89 ng ml−1 respectively. The precision of the method in terms of RSD was between 2–3%, and the sampling frequency was 100 h−1. In order to validate the proposed method, known concentrations of methyl mercury and inorganic mercury were spiked into deionized water and tap water samples. Certified reference materials (CRM) IAEA-085 and NRC DOLT-3 were analyzed after microwave assisted extraction with 6.0 mol l−1HCl solutions. Both inorganic mercury and methyl mercury concentrations were in agreement with the certified values.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A tungsten coil (150 W, 15 V) was used as the atomizer for the proposed Flow Injection Vapor Generation Atomic Absorption Spectrometry (FI-VGAAS) system to determine inorganic mercury and total mercury concentrations. In the proposed method inorganic mercury was measured when the W-coil is at room temperature and total mercury was measured when the W-coil temperature was set to 500 °C. The organic mercury concentration was calculated by subtracting the inorganic mercury concentration from the total mercury concentration. The calibration graphs were linear up to 100 ng ml−1. Limit of detection (LOD) values for inorganic mercury and methyl mercury were 0.60 ng ml−1 and 0.89 ng ml−1 respectively. The precision of the method in terms of RSD was between 2–3%, and the sampling frequency was 100 h−1. In order to validate the proposed method, known concentrations of methyl mercury and inorganic mercury were spiked into deionized water and tap water samples. Certified reference materials (CRM) IAEA-085 and NRC DOLT-3 were analyzed after microwave assisted extraction with 6.0 mol l−1HCl solutions. Both inorganic mercury and methyl mercury concentrations were in agreement with the certified values.

Key concepts: Mercury (programming language), Certified reference materials, Chemistry, Atomic absorption spectroscopy, Detection limit, Analytical Chemistry (journal), Cold vapour atomic fluorescence spectroscopy, Environmental chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of inorganic and total mercury by flow injection vapor generation atomic absorption spectrometry using a W-coil atomizer — Research Paper | ScholarLens