2010Gynecologic and Obstetric InvestigationRequires access

Cord Lactate, pH, and Blood Gases from Healthy Neonates

Terry Shirey, Jeanne St. Pierre, James Wirikelman

Open publisher page 23 citations

Abstract

Lactate, pH, pO2, and pCO2 were determined in arterial, venous, and free-flowing mixed umbilical cord blood obtained from deliveries of apparently healthy neonates. The goals of this study were to establish reference ranges for lactate and pH against which results in cases of high-risk labor and delivery could be compared, to see how the gases correlated with these values, and to determine whether easily accessible mixed umbilical cord blood can serve as the sample in lieu of cord arterial or cord venous blood. Arterial and venous cord lactates were 2.98 mmol/l (+/- 1.40) and 2.80 mmol/l (+/- 1.35), respectively, from 85 cords obtained from vaginal and cesarean deliveries. Mixed cord blood lactate, obtained on 48 cords, was 2.72 mmol/l (+/- 1.28) versus 3.14 and 2.97 mmol/l for the arterial and venous samples from those cords, respectively, and correlated quite well with lactate from the venous specimens (r = 0.97). Differences of > 0.5 mmol/l occurred between mixed and arterial cord bloods in 21 patients, and between mixed and venous cord bloods in 6 of the 48 patients, respectively. We conclude that (1) less than 2.5% of deliveries of apparently healthy neonates have arterial, venous, or mixed cord lactates > or = 7.0 mmol/l and pH < or = 7.15, (2) neither cord venous pO2 nor pCO2 correlate well with cord venous lactate, and (3) readily available mixed cord blood is a satisfactory specimen for the measurement of venous cord latate.

About this research paper

What this paper is about

Lactate, pH, pO2, and pCO2 were determined in arterial, venous, and free-flowing mixed umbilical cord blood obtained from deliveries of apparently healthy neonates. The goals of this study were to establish reference ranges for lactate and pH against which results in cases of high-risk labor and delivery could be compared, to see how the gases correlated with these values, and to determine whether easily accessible mixed umbilical cord blood can serve as the sample in lieu of cord arterial or cord venous blood. Arterial and venous cord lactates were 2.98 mmol/l (+/- 1.40) and 2.80 mmol/l (+/- 1.35), respectively, from 85 cords obtained from vaginal and cesarean deliveries. Mixed cord blood lactate, obtained on 48 cords, was 2.72 mmol/l (+/- 1.28) versus 3.14 and 2.97 mmol/l for the arterial and venous samples from those cords, respectively, and correlated quite well with lactate from the venous specimens (r = 0.97). Differences of > 0.5 mmol/l occurred between mixed and arterial cord bloods in 21 patients, and between mixed and venous cord bloods in 6 of the 48 patients, respectively. We conclude that (1) less than 2.5% of deliveries of apparently healthy neonates have arterial, venous, or mixed cord lactates > or = 7.0 mmol/l and pH < or = 7.15, (2) neither cord venous pO2 nor pCO2 correlate well with cord venous lactate, and (3) readily available mixed cord blood is a satisfactory specimen for the measurement of venous cord latate.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Lactate, pH, pO2, and pCO2 were determined in arterial, venous, and free-flowing mixed umbilical cord blood obtained from deliveries of apparently healthy neonates. The goals of this study were to establish reference ranges for lactate and pH against which results in cases of high-risk labor and delivery could be compared, to see how the gases correlated with these values, and to determine whether easily accessible mixed umbilical cord blood can serve as the sample in lieu of cord arterial or cord venous blood. Arterial and venous cord lactates were 2.98 mmol/l (+/- 1.40) and 2.80 mmol/l (+/- 1.35), respectively, from 85 cords obtained from vaginal and cesarean deliveries. Mixed cord blood lactate, obtained on 48 cords, was 2.72 mmol/l (+/- 1.28) versus 3.14 and 2.97 mmol/l for the arterial and venous samples from those cords, respectively, and correlated quite well with lactate from the venous specimens (r = 0.97). Differences of > 0.5 mmol/l occurred between mixed and arterial cord bloods in 21 patients, and between mixed and venous cord bloods in 6 of the 48 patients, respectively. We conclude that (1) less than 2.5% of deliveries of apparently healthy neonates have arterial, venous, or mixed cord lactates > or = 7.0 mmol/l and pH < or = 7.15, (2) neither cord venous pO2 nor pCO2 correlate well with cord venous lactate, and (3) readily available mixed cord blood is a satisfactory specimen for the measurement of venous cord latate.

Key concepts: Cord, Medicine, Umbilical cord, Venous blood, Cord blood, pCO2, Anesthesia, Arterial blood

Related papers

Back to paper searchBrowse research topicsOriginal source
Cord Lactate, pH, and Blood Gases from Healthy Neonates — Research Paper | ScholarLens