2006Knee Surgery Sports Traumatology ArthroscopyRequires access

Early results of high‐flex total knee arthroplasty: comparison study at 1 year after surgery

Seong Il Bin, Tae-Seok Nam

Open publisher page 122 citations

Abstract

We compared clinical [including maximal flexion and range of motion (ROM)] and radiographical outcomes of high-flex versus conventional implants for total knee arthroplasty (TKA) after 1 year. We also analyzed the factors affecting postoperative ROM in high-flex implants. The high-flex group (n=90) had an average maximal flexion of 129.8 degrees (standard deviation (SD), 5.2 degrees ) significantly higher than the 124.3 degrees (SD, 9.2 degrees ) of the conventional group (n=90), especially for patients with less than 90 degrees of knee flexion (P<0.05). There was no significant difference in hospital for special surgery (HSS) score between the two groups. No knee developed osteolysis, aseptic loosening, or other complications. We found that, for high-flex implants, preoperative ROM had a significant effect on postoperative ROM.

About this research paper

What this paper is about

We compared clinical [including maximal flexion and range of motion (ROM)] and radiographical outcomes of high-flex versus conventional implants for total knee arthroplasty (TKA) after 1 year. We also analyzed the factors affecting postoperative ROM in high-flex implants. The high-flex group (n=90) had an average maximal flexion of 129.8 degrees (standard deviation (SD), 5.2 degrees ) significantly higher than the 124.3 degrees (SD, 9.2 degrees ) of the conventional group (n=90), especially for patients with less than 90 degrees of knee flexion (P<0.05). There was no significant difference in hospital for special surgery (HSS) score between the two groups. No knee developed osteolysis, aseptic loosening, or other complications. We found that, for high-flex implants, preoperative ROM had a significant effect on postoperative ROM.

Why it matters

OpenAlex reports 122 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared clinical [including maximal flexion and range of motion (ROM)] and radiographical outcomes of high-flex versus conventional implants for total knee arthroplasty (TKA) after 1 year. We also analyzed the factors affecting postoperative ROM in high-flex implants. The high-flex group (n=90) had an average maximal flexion of 129.8 degrees (standard deviation (SD), 5.2 degrees ) significantly higher than the 124.3 degrees (SD, 9.2 degrees ) of the conventional group (n=90), especially for patients with less than 90 degrees of knee flexion (P<0.05). There was no significant difference in hospital for special surgery (HSS) score between the two groups. No knee developed osteolysis, aseptic loosening, or other complications. We found that, for high-flex implants, preoperative ROM had a significant effect on postoperative ROM.

Key concepts: FLEX, Medicine, Osteolysis, Range of motion, Total knee arthroplasty, Arthroplasty, Surgery, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Early results of high‐flex total knee arthroplasty: comparison study at 1 year after surgery — Research Paper | ScholarLens