2002•RadiologyRequires access

Covered, Retrievable, Expandable Urethral Nitinol Stent: Feasibility Study in Dogs

Gi‐Young Ko, Gab-Cheol Kim, Tae-Seok Seo, Tae Hyung Kim, Jin-Oh Lim, Jong-Heon Lee, Ho-Young Song

Open publisher page 28 citations

Abstract

PURPOSE: To evaluate the feasibility of using a retrievable urethral stent and to evaluate whether granulation tissue resolves after stent removal in a canine urethra. MATERIALS AND METHODS: Polyurethane-covered retrievable 0.10-mm-thick (n = 11) or 0.15-mm-thick (n = 10) nitinol wire stents were placed in the urethras of 20 dogs. In one dog, a second stent was placed in the urethra because of complete migration of the first stent into the urinary bladder. The stents were removed with retrieval hook wires 4 weeks (n = 10) and 8 weeks (n = 10) after placement. Fourteen dogs were sacrificed just after stent removal, and the other six dogs were sacrificed 2 weeks after stent removal. Information concerning procedure success, stent migration, and tissue response was obtained. RESULTS: Stent placement was technically successful in all dogs. Follow-up urethrograms showed partial (n = 4) or complete (n = 1) stent migration. Stent removal failed in two dogs due to partial or complete migration. Granulation tissue was observed at both ends of the stent in 17 dogs. Urethrograms and urethral specimens obtained 2 weeks after stent removal showed diminished granulation tissue and decreased thickness of the papillary projections of the epithelium compared with results obtained immediately after stent removal. CONCLUSION: Although some design modifications are necessary to reduce current complications, the polyurethane-covered retrievable nitinol stent seems feasible for use in the urethra. Stent-induced granulation tissue formation improved after stent removal.

About this research paper

What this paper is about

PURPOSE: To evaluate the feasibility of using a retrievable urethral stent and to evaluate whether granulation tissue resolves after stent removal in a canine urethra. MATERIALS AND METHODS: Polyurethane-covered retrievable 0.10-mm-thick (n = 11) or 0.15-mm-thick (n = 10) nitinol wire stents were placed in the urethras of 20 dogs. In one dog, a second stent was placed in the urethra because of complete migration of the first stent into the urinary bladder. The stents were removed with retrieval hook wires 4 weeks (n = 10) and 8 weeks (n = 10) after placement. Fourteen dogs were sacrificed just after stent removal, and the other six dogs were sacrificed 2 weeks after stent removal. Information concerning procedure success, stent migration, and tissue response was obtained. RESULTS: Stent placement was technically successful in all dogs. Follow-up urethrograms showed partial (n = 4) or complete (n = 1) stent migration. Stent removal failed in two dogs due to partial or complete migration. Granulation tissue was observed at both ends of the stent in 17 dogs. Urethrograms and urethral specimens obtained 2 weeks after stent removal showed diminished granulation tissue and decreased thickness of the papillary projections of the epithelium compared with results obtained immediately after stent removal. CONCLUSION: Although some design modifications are necessary to reduce current complications, the polyurethane-covered retrievable nitinol stent seems feasible for use in the urethra. Stent-induced granulation tissue formation improved after stent removal.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the feasibility of using a retrievable urethral stent and to evaluate whether granulation tissue resolves after stent removal in a canine urethra. MATERIALS AND METHODS: Polyurethane-covered retrievable 0.10-mm-thick (n = 11) or 0.15-mm-thick (n = 10) nitinol wire stents were placed in the urethras of 20 dogs. In one dog, a second stent was placed in the urethra because of complete migration of the first stent into the urinary bladder. The stents were removed with retrieval hook wires 4 weeks (n = 10) and 8 weeks (n = 10) after placement. Fourteen dogs were sacrificed just after stent removal, and the other six dogs were sacrificed 2 weeks after stent removal. Information concerning procedure success, stent migration, and tissue response was obtained. RESULTS: Stent placement was technically successful in all dogs. Follow-up urethrograms showed partial (n = 4) or complete (n = 1) stent migration. Stent removal failed in two dogs due to partial or complete migration. Granulation tissue was observed at both ends of the stent in 17 dogs. Urethrograms and urethral specimens obtained 2 weeks after stent removal showed diminished granulation tissue and decreased thickness of the papillary projections of the epithelium compared with results obtained immediately after stent removal. CONCLUSION: Although some design modifications are necessary to reduce current complications, the polyurethane-covered retrievable nitinol stent seems feasible for use in the urethra. Stent-induced granulation tissue formation improved after stent removal.

Key concepts: Stent, Medicine, Granulation tissue, Urethra, Surgery, Radiology, Wound healing

Related papers

Back to paper searchBrowse research topicsOriginal source
Covered, Retrievable, Expandable Urethral Nitinol Stent: Feasibility Study in Dogs — Research Paper | ScholarLens