1981•Scandinavian Journal of Clinical and Laboratory InvestigationRequires access

A comparison of a new miniphotometer (Compur M 1002) with the routine laboratory method for blood glucose determination

Klaus Kølendorf, Steen Clausen, Annette Lykke Svenningsen

Open publisher page 1 citations

Abstract

A recently marketed portable miniphotometer (Compur M 1002) which measures blood glucose concentration (BG) in disposable reagent-containing cuvettes was investigated. Dimensions are: 177±78±32 mm, weight 340 g with rechargeable batteries. Two hundred and forty-nine blood samples were analysed in duplicate and compared with the routine laboratory method, both using glucose-oxidase peroxidase a.m. Trinder. The correlation was highly significant (r=0.9919, P < 0.001, y=0.3712+ 1.0258x). Five μl of blood or plasma are requested. The duration of BG determination is 8—9 min per analysis. The intra-assay CV was 2.2—2.6% for the Compur and 1.1—3.3% for the reference method. The interassay CV was 2.0—5.0% and 2.1—3.9%, respectively. Recovery was 96—106%. Seventeen untrained diabetics used the miniphotometer without difficulty.

About this research paper

What this paper is about

A recently marketed portable miniphotometer (Compur M 1002) which measures blood glucose concentration (BG) in disposable reagent-containing cuvettes was investigated. Dimensions are: 177±78±32 mm, weight 340 g with rechargeable batteries. Two hundred and forty-nine blood samples were analysed in duplicate and compared with the routine laboratory method, both using glucose-oxidase peroxidase a.m. Trinder. The correlation was highly significant (r=0.9919, P < 0.001, y=0.3712+ 1.0258x). Five μl of blood or plasma are requested. The duration of BG determination is 8—9 min per analysis. The intra-assay CV was 2.2—2.6% for the Compur and 1.1—3.3% for the reference method. The interassay CV was 2.0—5.0% and 2.1—3.9%, respectively. Recovery was 96—106%. Seventeen untrained diabetics used the miniphotometer without difficulty.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A recently marketed portable miniphotometer (Compur M 1002) which measures blood glucose concentration (BG) in disposable reagent-containing cuvettes was investigated. Dimensions are: 177±78±32 mm, weight 340 g with rechargeable batteries. Two hundred and forty-nine blood samples were analysed in duplicate and compared with the routine laboratory method, both using glucose-oxidase peroxidase a.m. Trinder. The correlation was highly significant (r=0.9919, P < 0.001, y=0.3712+ 1.0258x). Five μl of blood or plasma are requested. The duration of BG determination is 8—9 min per analysis. The intra-assay CV was 2.2—2.6% for the Compur and 1.1—3.3% for the reference method. The interassay CV was 2.0—5.0% and 2.1—3.9%, respectively. Recovery was 96—106%. Seventeen untrained diabetics used the miniphotometer without difficulty.

Key concepts: Cuvette, Glucose oxidase, Chromatography, Chemistry, Reagent, Plasma glucose, Medicine, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparison of a new miniphotometer (Compur M 1002) with the routine laboratory method for blood glucose determination — Research Paper | ScholarLens