1985•IEEE Transactions on Nuclear ScienceOpen access

Transverse Emittance of a 2.0-MeV RFQ Beam with High Brightness

Oscar R. Sander, G.P. Boicourt, William B. Cottingame

Open full text 4 citations

Abstract

One major purpose of the accelerator test stand (ATS) is to see if particle simulation codes can correctly predict the output beam parameters of our radiofrequency quadrupole (RFQ) linac. By injecting a very bright 100-keV beam (100 mA, 0.02 π.cm.mrad) and comparing the measured output beam parameters with those predicted (using PARMTEQ), we can investigate PARMTEQ's performance in a high space-charge regime. PARMTEQ has successfully simulated the RFQ beam transmission and energy distribution; it is more difficult to simulate output transverse emittance. Transverse emittance is also difficult to measure because of the high-power-density beam. Special modification of our interceptive slit and collector equipment was required. This paper will compare measured transverse emittances with those predicted.

Open-access reader

About this research paper

What this paper is about

One major purpose of the accelerator test stand (ATS) is to see if particle simulation codes can correctly predict the output beam parameters of our radiofrequency quadrupole (RFQ) linac. By injecting a very bright 100-keV beam (100 mA, 0.02 π.cm.mrad) and comparing the measured output beam parameters with those predicted (using PARMTEQ), we can investigate PARMTEQ's performance in a high space-charge regime. PARMTEQ has successfully simulated the RFQ beam transmission and energy distribution; it is more difficult to simulate output transverse emittance. Transverse emittance is also difficult to measure because of the high-power-density beam. Special modification of our interceptive slit and collector equipment was required. This paper will compare measured transverse emittances with those predicted.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One major purpose of the accelerator test stand (ATS) is to see if particle simulation codes can correctly predict the output beam parameters of our radiofrequency quadrupole (RFQ) linac. By injecting a very bright 100-keV beam (100 mA, 0.02 π.cm.mrad) and comparing the measured output beam parameters with those predicted (using PARMTEQ), we can investigate PARMTEQ's performance in a high space-charge regime. PARMTEQ has successfully simulated the RFQ beam transmission and energy distribution; it is more difficult to simulate output transverse emittance. Transverse emittance is also difficult to measure because of the high-power-density beam. Special modification of our interceptive slit and collector equipment was required. This paper will compare measured transverse emittances with those predicted.

Key concepts: Thermal emittance, Beam emittance, Beam (structure), Linear particle accelerator, Physics, Transverse plane, Particle accelerator, Brightness

Related papers

Back to paper searchBrowse research topicsOriginal source
Transverse Emittance of a 2.0-MeV RFQ Beam with High Brightness — Research Paper | ScholarLens