2011•Journal of Surface Investigation X-ray Synchrotron and Neutron TechniquesRequires access

Commissioning experience with insertion devices at PETRA III

Pavel Vagin, Uwe ENGLISCH, Timo Müller, A. Schöps, Matthias Tischer

Open publisher page 9 citations

Abstract

PETRA III is a new hard X-ray synchrotron radiation source, operating at 6 GeV with a beam current of up to 100 mA and extremely low horizontal emittance of 1 nm rad. Such low emittance is achieved by using two 100 m long damping wiggler sections which reduce the emittance by a factor of 4. Altogether the damping sections contain 20 wigglers of 4m length each. The emitted synchrotron radiation power produced by wigglers amounts to 420 kW at 100 mA beam current in total. In the new octant of PETRA III, there are 14 undulator beamlines, with a brilliance up to 10 21 (s mrad 2 mm 2 0.1% BW) −1 which cover an energy range from 0.3 keV to more than 100 keV. The low emittance raises very high requirements to the field quality of the insertion devices. At first, it should not affect the positron beam trajectory. Secondly, the spectral properties of the radiation created, like the intensity of higher harmonics, should not be limited by the undulator field quality, but by the beam emittance effects in order to have some reserve for future machine upgrades or possible radiation demagnetization. This paper presents the current status of PETRA III insertion devices and describes intermediate commissioning results like impact of IDs on the positron beam orbit or photon beam and radiation problems.

About this research paper

What this paper is about

PETRA III is a new hard X-ray synchrotron radiation source, operating at 6 GeV with a beam current of up to 100 mA and extremely low horizontal emittance of 1 nm rad. Such low emittance is achieved by using two 100 m long damping wiggler sections which reduce the emittance by a factor of 4. Altogether the damping sections contain 20 wigglers of 4m length each. The emitted synchrotron radiation power produced by wigglers amounts to 420 kW at 100 mA beam current in total. In the new octant of PETRA III, there are 14 undulator beamlines, with a brilliance up to 10 21 (s mrad 2 mm 2 0.1% BW) −1 which cover an energy range from 0.3 keV to more than 100 keV. The low emittance raises very high requirements to the field quality of the insertion devices. At first, it should not affect the positron beam trajectory. Secondly, the spectral properties of the radiation created, like the intensity of higher harmonics, should not be limited by the undulator field quality, but by the beam emittance effects in order to have some reserve for future machine upgrades or possible radiation demagnetization. This paper presents the current status of PETRA III insertion devices and describes intermediate commissioning results like impact of IDs on the positron beam orbit or photon beam and radiation problems.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PETRA III is a new hard X-ray synchrotron radiation source, operating at 6 GeV with a beam current of up to 100 mA and extremely low horizontal emittance of 1 nm rad. Such low emittance is achieved by using two 100 m long damping wiggler sections which reduce the emittance by a factor of 4. Altogether the damping sections contain 20 wigglers of 4m length each. The emitted synchrotron radiation power produced by wigglers amounts to 420 kW at 100 mA beam current in total. In the new octant of PETRA III, there are 14 undulator beamlines, with a brilliance up to 10 21 (s mrad 2 mm 2 0.1% BW) −1 which cover an energy range from 0.3 keV to more than 100 keV. The low emittance raises very high requirements to the field quality of the insertion devices. At first, it should not affect the positron beam trajectory. Secondly, the spectral properties of the radiation created, like the intensity of higher harmonics, should not be limited by the undulator field quality, but by the beam emittance effects in order to have some reserve for future machine upgrades or possible radiation demagnetization. This paper presents the current status of PETRA III insertion devices and describes intermediate commissioning results like impact of IDs on the positron beam orbit or photon beam and radiation problems.

Key concepts: Thermal emittance, Wiggler, Undulator, Physics, Synchrotron radiation, Optics, Beam (structure), Beam emittance