2010Physiological MeasurementOpen access

The sensitivity of focused electrical impedance measurements

Naimul Islam, K Siddique-e Rabbani, Adrian J. Wilson

Open full text 33 citations

Abstract

One of the problems with tetrapolar impedance measurements is the lack of spatial sensitivity within the measured volume. In this paper we compare the sensitivity of tetrapolar measurements and the focused impedance measurements (FIM) proposed by Rabbani et al (1999 Ann. New York Acad. Sci. 873 408-20), which give an improved sensitivity profile. Using a previously validated model of sensitivity based on Geselowitz's lead theory, the sensitivity of FIM using eight, six and four electrodes was investigated. All electrode configurations showed a maximum in the average sensitivity of a plane at a depth of one-third of the drive-receive electrode spacing. No difference was found in the sensitivity value of this maximum between electrode configurations having the same drive-receive electrode spacing. The six- and eight-electrode configurations showed negative sensitivity regions down to half of the drive-receive electrode spacing, whilst the four-electrode measurement showed negative sensitivity regions down to one-third of the drive-receive electrode spacing. The single peak in sensitivity beneath the centre of the electrode configuration became dominant at 0.56, 1.4 and 0.14 of the receive electrode spacing for the eight-, six- and four-electrode configurations respectively. Thus, the four-electrode FIM configuration gives a single peak closest to the surface.

Open-access reader

About this research paper

What this paper is about

One of the problems with tetrapolar impedance measurements is the lack of spatial sensitivity within the measured volume. In this paper we compare the sensitivity of tetrapolar measurements and the focused impedance measurements (FIM) proposed by Rabbani et al (1999 Ann. New York Acad. Sci. 873 408-20), which give an improved sensitivity profile. Using a previously validated model of sensitivity based on Geselowitz's lead theory, the sensitivity of FIM using eight, six and four electrodes was investigated. All electrode configurations showed a maximum in the average sensitivity of a plane at a depth of one-third of the drive-receive electrode spacing. No difference was found in the sensitivity value of this maximum between electrode configurations having the same drive-receive electrode spacing. The six- and eight-electrode configurations showed negative sensitivity regions down to half of the drive-receive electrode spacing, whilst the four-electrode measurement showed negative sensitivity regions down to one-third of the drive-receive electrode spacing. The single peak in sensitivity beneath the centre of the electrode configuration became dominant at 0.56, 1.4 and 0.14 of the receive electrode spacing for the eight-, six- and four-electrode configurations respectively. Thus, the four-electrode FIM configuration gives a single peak closest to the surface.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One of the problems with tetrapolar impedance measurements is the lack of spatial sensitivity within the measured volume. In this paper we compare the sensitivity of tetrapolar measurements and the focused impedance measurements (FIM) proposed by Rabbani et al (1999 Ann. New York Acad. Sci. 873 408-20), which give an improved sensitivity profile. Using a previously validated model of sensitivity based on Geselowitz's lead theory, the sensitivity of FIM using eight, six and four electrodes was investigated. All electrode configurations showed a maximum in the average sensitivity of a plane at a depth of one-third of the drive-receive electrode spacing. No difference was found in the sensitivity value of this maximum between electrode configurations having the same drive-receive electrode spacing. The six- and eight-electrode configurations showed negative sensitivity regions down to half of the drive-receive electrode spacing, whilst the four-electrode measurement showed negative sensitivity regions down to one-third of the drive-receive electrode spacing. The single peak in sensitivity beneath the centre of the electrode configuration became dominant at 0.56, 1.4 and 0.14 of the receive electrode spacing for the eight-, six- and four-electrode configurations respectively. Thus, the four-electrode FIM configuration gives a single peak closest to the surface.

Key concepts: Electrode, Sensitivity (control systems), Materials science, Electrical impedance, Analytical Chemistry (journal), Electrical engineering, Chemistry, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
The sensitivity of focused electrical impedance measurements — Research Paper | ScholarLens