2005•Aerosol Science and TechnologyOpen access

Size Distribution Evolution of Fine Aerosols Due to Intercoagulation with Coarse Aerosols

Sang-Rin Lee, Chang‐Yu Wu

Open full text 20 citations

Abstract

Controlling the emission of submicron particles of toxic metals in a combustion system poses a challenge. One possible mechanism for removing these fine particles is through intercoagulation with coarse particles. A bimodal lognormal model was applied to investigate the impact of intercoagulation rate on the size distributions of fine-mode aerosols. Fine-mode particle removal time was found to depend strongly on the number concentration of coarse-mode particles, but it was independent on the number concentration of fine-mode particles. An increase of geometric standard deviation of fine-mode particles from 1 to 1.6 significantly increased the dimensionless removal time 27 times. On the contrary, an increase of the deviation of coarse-mode particles in the same range only decreased 3% of the dimensionless removal time. The variation of geometric mean size ratio, meanwhile, had only insignificant effects on dimensionless removal time. For a constant mass concentration, removal time decreased as geometric standard deviation narrowed and mean size of coarse mode decreased. Fine-mode particles ultimately approached monodisperse when the dominant mechanism was intercoagulation; meanwhile, coarse-mode particles approached the asymptotic shape because intracoagulation was the dominant mechanism. The results show that on a constant mass basis, monodisperse coarse-mode particles with a high number concentration are the optimal condition for enhanced removal of fine-mode particles through intercoagulation.

Open-access reader

About this research paper

What this paper is about

Controlling the emission of submicron particles of toxic metals in a combustion system poses a challenge. One possible mechanism for removing these fine particles is through intercoagulation with coarse particles. A bimodal lognormal model was applied to investigate the impact of intercoagulation rate on the size distributions of fine-mode aerosols. Fine-mode particle removal time was found to depend strongly on the number concentration of coarse-mode particles, but it was independent on the number concentration of fine-mode particles. An increase of geometric standard deviation of fine-mode particles from 1 to 1.6 significantly increased the dimensionless removal time 27 times. On the contrary, an increase of the deviation of coarse-mode particles in the same range only decreased 3% of the dimensionless removal time. The variation of geometric mean size ratio, meanwhile, had only insignificant effects on dimensionless removal time. For a constant mass concentration, removal time decreased as geometric standard deviation narrowed and mean size of coarse mode decreased. Fine-mode particles ultimately approached monodisperse when the dominant mechanism was intercoagulation; meanwhile, coarse-mode particles approached the asymptotic shape because intracoagulation was the dominant mechanism. The results show that on a constant mass basis, monodisperse coarse-mode particles with a high number concentration are the optimal condition for enhanced removal of fine-mode particles through intercoagulation.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Controlling the emission of submicron particles of toxic metals in a combustion system poses a challenge. One possible mechanism for removing these fine particles is through intercoagulation with coarse particles. A bimodal lognormal model was applied to investigate the impact of intercoagulation rate on the size distributions of fine-mode aerosols. Fine-mode particle removal time was found to depend strongly on the number concentration of coarse-mode particles, but it was independent on the number concentration of fine-mode particles. An increase of geometric standard deviation of fine-mode particles from 1 to 1.6 significantly increased the dimensionless removal time 27 times. On the contrary, an increase of the deviation of coarse-mode particles in the same range only decreased 3% of the dimensionless removal time. The variation of geometric mean size ratio, meanwhile, had only insignificant effects on dimensionless removal time. For a constant mass concentration, removal time decreased as geometric standard deviation narrowed and mean size of coarse mode decreased. Fine-mode particles ultimately approached monodisperse when the dominant mechanism was intercoagulation; meanwhile, coarse-mode particles approached the asymptotic shape because intracoagulation was the dominant mechanism. The results show that on a constant mass basis, monodisperse coarse-mode particles with a high number concentration are the optimal condition for enhanced removal of fine-mode particles through intercoagulation.

Key concepts: Dimensionless quantity, Geometric standard deviation, Log-normal distribution, Dispersity, Particle size, Range (aeronautics), Mass concentration (chemistry), Mode (computer interface)

Related papers

Back to paper searchBrowse research topicsOriginal source
Size Distribution Evolution of Fine Aerosols Due to Intercoagulation with Coarse Aerosols — Research Paper | ScholarLens