2011•Arabian Journal of ChemistryOpen access

A modified high-performance liquid chromatographic method for the analysis of pantoprazole sodium in pharmaceutical dosage forms using lansoprazole as internal standard

Safwan Ashour, Soulafa Omar

Open full text 20 citations

Abstract

A Simple and rapid reversed-phase high-performance liquid chromatographic method for the direct determination of pantoprazole in pharmaceutical dosage forms was developed and validated. Lansoprazole was used as internal standard. The chromatographic separation of pantoprazole and lansoprazole was achieved on a Nucleodur C8 column (250 × 4.6 mm i.d., 5 μm particle size) using the photodiode array detector at 280 nm. The optimized mobile phase was consisted of a mixture of 0.1 M ammonium acetate solution and methanol (42:58, v/v), pumped at a flow rate 1.0 mL min−1. The retention times for pantoprazole and lansoprazole were 8.10 and 11.15 min, respectively. Linearity range was 3.06–1243.0 μg mL−1 with limit of detection value of 0.78 μg mL−1. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.07%, while the recovery was 99.07–103.95%. No interference from any components of pharmaceutical dosage forms or degradation products was observed. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the quantitative analysis of pantoprazole in tablets.

About this research paper

What this paper is about

A Simple and rapid reversed-phase high-performance liquid chromatographic method for the direct determination of pantoprazole in pharmaceutical dosage forms was developed and validated. Lansoprazole was used as internal standard. The chromatographic separation of pantoprazole and lansoprazole was achieved on a Nucleodur C8 column (250 × 4.6 mm i.d., 5 μm particle size) using the photodiode array detector at 280 nm. The optimized mobile phase was consisted of a mixture of 0.1 M ammonium acetate solution and methanol (42:58, v/v), pumped at a flow rate 1.0 mL min−1. The retention times for pantoprazole and lansoprazole were 8.10 and 11.15 min, respectively. Linearity range was 3.06–1243.0 μg mL−1 with limit of detection value of 0.78 μg mL−1. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.07%, while the recovery was 99.07–103.95%. No interference from any components of pharmaceutical dosage forms or degradation products was observed. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the quantitative analysis of pantoprazole in tablets.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A Simple and rapid reversed-phase high-performance liquid chromatographic method for the direct determination of pantoprazole in pharmaceutical dosage forms was developed and validated. Lansoprazole was used as internal standard. The chromatographic separation of pantoprazole and lansoprazole was achieved on a Nucleodur C8 column (250 × 4.6 mm i.d., 5 μm particle size) using the photodiode array detector at 280 nm. The optimized mobile phase was consisted of a mixture of 0.1 M ammonium acetate solution and methanol (42:58, v/v), pumped at a flow rate 1.0 mL min−1. The retention times for pantoprazole and lansoprazole were 8.10 and 11.15 min, respectively. Linearity range was 3.06–1243.0 μg mL−1 with limit of detection value of 0.78 μg mL−1. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.07%, while the recovery was 99.07–103.95%. No interference from any components of pharmaceutical dosage forms or degradation products was observed. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the quantitative analysis of pantoprazole in tablets.

Key concepts: Chemistry, Lansoprazole, Pantoprazole, Chromatography, Dosage form, Detection limit, Pharmaceutical formulation, Chromatographic separation

Related papers

Back to paper searchBrowse research topicsOriginal source
A modified high-performance liquid chromatographic method for the analysis of pantoprazole sodium in pharmaceutical dosage forms using lansoprazole as internal standard — Research Paper | ScholarLens