1980Publications of the Astronomical Society of the PacificOpen access

An f/35 submillimeter photometer for the NASA infrared telescope facility

S. E. Whitcomb, R. H. Hildebrand, J. Keene

Open full text 11 citations

Abstract

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Open-access reader

About this research paper

What this paper is about

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Key concepts: Photometer, Telescope, Infrared telescope, Infrared, Astronomy, Physics, Infrared astronomy, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
An f/35 submillimeter photometer for the NASA infrared telescope facility — Research Paper | ScholarLens