2002Acta Anaesthesiologica ScandinavicaRequires access

Coiling of lumbar epidural catheters

Young‐Jin Lim, Jae-Hyon Bahk, Wonsik Ahn, S. C. Lee

Open publisher page 41 citations

Abstract

BACKGROUND: The difficulties in threading an epidural catheter to vertebral levels remote to the puncture level have been well documented. This study was undertaken to determine the length that a single orifice epidural catheter can be threaded into the lumbar space without coiling (coiling length), and whether this is affected by the direction of the epidural needle bevel. METHODS: Forty-five young male patients scheduled for surgery under epidural analgesia were enrolled. The epidural space was identified using a midline approach at the L(2-3) or L(3-4) interspace with the loss of resistance to air technique. A 19-G single-orifice epidural catheter (Flextip Plus, Arrow International, Inc, Reading, PA, USA) was inserted through a Tuohy needle oriented either cephalad (n=20) or caudad (n=25). During insertion, the path and the position of the catheter tip was determined by fluoroscopy using iohexol dye. RESULTS: The median coiling length was 2.8 cm, ranging from 1.0 to 8.0 cm. Only 13% of epidural catheters could be threaded 4 cm beyond the tip of the needle without coiling. No significant difference was found in coiling length between the cephalad group (2.9 cm) and the caudad group (2.5 cm). CONCLUSION: This study demonstrates that coiling length is independent of whether the bevel of the Tuohy needle is directed cephalad or caudad. We recommend that an optimal insertion depth of an end-hole single orifice catheter is 3 cm.

About this research paper

What this paper is about

BACKGROUND: The difficulties in threading an epidural catheter to vertebral levels remote to the puncture level have been well documented. This study was undertaken to determine the length that a single orifice epidural catheter can be threaded into the lumbar space without coiling (coiling length), and whether this is affected by the direction of the epidural needle bevel. METHODS: Forty-five young male patients scheduled for surgery under epidural analgesia were enrolled. The epidural space was identified using a midline approach at the L(2-3) or L(3-4) interspace with the loss of resistance to air technique. A 19-G single-orifice epidural catheter (Flextip Plus, Arrow International, Inc, Reading, PA, USA) was inserted through a Tuohy needle oriented either cephalad (n=20) or caudad (n=25). During insertion, the path and the position of the catheter tip was determined by fluoroscopy using iohexol dye. RESULTS: The median coiling length was 2.8 cm, ranging from 1.0 to 8.0 cm. Only 13% of epidural catheters could be threaded 4 cm beyond the tip of the needle without coiling. No significant difference was found in coiling length between the cephalad group (2.9 cm) and the caudad group (2.5 cm). CONCLUSION: This study demonstrates that coiling length is independent of whether the bevel of the Tuohy needle is directed cephalad or caudad. We recommend that an optimal insertion depth of an end-hole single orifice catheter is 3 cm.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The difficulties in threading an epidural catheter to vertebral levels remote to the puncture level have been well documented. This study was undertaken to determine the length that a single orifice epidural catheter can be threaded into the lumbar space without coiling (coiling length), and whether this is affected by the direction of the epidural needle bevel. METHODS: Forty-five young male patients scheduled for surgery under epidural analgesia were enrolled. The epidural space was identified using a midline approach at the L(2-3) or L(3-4) interspace with the loss of resistance to air technique. A 19-G single-orifice epidural catheter (Flextip Plus, Arrow International, Inc, Reading, PA, USA) was inserted through a Tuohy needle oriented either cephalad (n=20) or caudad (n=25). During insertion, the path and the position of the catheter tip was determined by fluoroscopy using iohexol dye. RESULTS: The median coiling length was 2.8 cm, ranging from 1.0 to 8.0 cm. Only 13% of epidural catheters could be threaded 4 cm beyond the tip of the needle without coiling. No significant difference was found in coiling length between the cephalad group (2.9 cm) and the caudad group (2.5 cm). CONCLUSION: This study demonstrates that coiling length is independent of whether the bevel of the Tuohy needle is directed cephalad or caudad. We recommend that an optimal insertion depth of an end-hole single orifice catheter is 3 cm.

Key concepts: Tuohy needle, Medicine, Bevel, Epidural space, Catheter, Fluoroscopy, Lumbar, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Coiling of lumbar epidural catheters — Research Paper | ScholarLens