2005•Cochlear Implants InternationalRequires access

Psychoacoustic dynamic range and cochlear implant speech-perception performance in Nucleus 22 users

Ricardo Ferreira Bento, Rubens Vuono de Brito Neto, Arthur Menino Castilho, María Valéria Schmidt Goffi-Gómez, Sandra B. Giorgi Sant’Anna, Mariana Cardoso Guedes, Cristina Gomes De Ornelas Peralta

Open publisher page 10 citations

Abstract

BACKGROUND: Cochlear implant speech processors compress a wide acoustical dynamic range of sounds into a smaller electrical dynamic range. Some patients show wider electrical dynamic ranges than others and most of them have good speech perception performance. The knowledge of the average psycho-acoustical dynamic range in adults will help the audiologist program children who do not give reliable responses. AIM: This study was conducted to analyse the dynamic ranges of experienced Nucleus 22 cochlear implant users with good speech-perception and patients with poor speech-perception performances. METHOD: Thirty-one maps of adult subjects with Nucleus 22 cochlear implants using the SPEAK processing strategy, in bipolar stimulation were analysed. By the time of this study, all of them had used a cochlear implant for over a year. They were divided into two groups: group 1, composed of those with good speech perception for sentences (better than 80%), and group 2, composed of those with speech perception results for sentences worse than 70%. RESULTS: Results showed that both dynamic ranges were wide in the two groups (average 50 units). CONCLUSION: Although dynamic ranges vary among subjects and electrodes, a lower variability was observed within the group of patients with better speech perception.

About this research paper

What this paper is about

BACKGROUND: Cochlear implant speech processors compress a wide acoustical dynamic range of sounds into a smaller electrical dynamic range. Some patients show wider electrical dynamic ranges than others and most of them have good speech perception performance. The knowledge of the average psycho-acoustical dynamic range in adults will help the audiologist program children who do not give reliable responses. AIM: This study was conducted to analyse the dynamic ranges of experienced Nucleus 22 cochlear implant users with good speech-perception and patients with poor speech-perception performances. METHOD: Thirty-one maps of adult subjects with Nucleus 22 cochlear implants using the SPEAK processing strategy, in bipolar stimulation were analysed. By the time of this study, all of them had used a cochlear implant for over a year. They were divided into two groups: group 1, composed of those with good speech perception for sentences (better than 80%), and group 2, composed of those with speech perception results for sentences worse than 70%. RESULTS: Results showed that both dynamic ranges were wide in the two groups (average 50 units). CONCLUSION: Although dynamic ranges vary among subjects and electrodes, a lower variability was observed within the group of patients with better speech perception.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Cochlear implant speech processors compress a wide acoustical dynamic range of sounds into a smaller electrical dynamic range. Some patients show wider electrical dynamic ranges than others and most of them have good speech perception performance. The knowledge of the average psycho-acoustical dynamic range in adults will help the audiologist program children who do not give reliable responses. AIM: This study was conducted to analyse the dynamic ranges of experienced Nucleus 22 cochlear implant users with good speech-perception and patients with poor speech-perception performances. METHOD: Thirty-one maps of adult subjects with Nucleus 22 cochlear implants using the SPEAK processing strategy, in bipolar stimulation were analysed. By the time of this study, all of them had used a cochlear implant for over a year. They were divided into two groups: group 1, composed of those with good speech perception for sentences (better than 80%), and group 2, composed of those with speech perception results for sentences worse than 70%. RESULTS: Results showed that both dynamic ranges were wide in the two groups (average 50 units). CONCLUSION: Although dynamic ranges vary among subjects and electrodes, a lower variability was observed within the group of patients with better speech perception.

Key concepts: Cochlear implant, Audiologist, Speech perception, Audiology, Perception, Psychoacoustics, Dynamic range, Auditory perception

Related papers

Back to paper searchBrowse research topicsOriginal source
Psychoacoustic dynamic range and cochlear implant speech-perception performance in Nucleus 22 users — Research Paper | ScholarLens