A Multicenter Evaluation of the Iris iQ200 Automated Urine Microscopy Analyzer Body Fluids Module and Comparison With Hemacytometer Cell Counts

Anthony W. Butch, Porntip K. Wises, David T. Wah, Terrie G. Gornet, Herbert A. Fritsche

Open full text 20 citations

Abstract

Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (CV), ranged from 2.6% to 5.9% for RBC counts between 875 and 475 x 10(6)/L and from 4.2% to 6.5% for nucleated cell counts between 820 and 590 x 10(6)/L. The lower limits of detection, based on a CV of 20% or less, were 30 and 35 x 10(6)/L for RBCs and nucleated cells, respectively. There was very good agreement between automated iQ200 and manual body fluid cell counts based on slopes and r2 values. The iQ200 has satisfactory performance for enumerating RBCs and nucleated cells in most body fluids, with the exception of cerebrospinal fluid specimens that contain low cell numbers.

Open-access reader

About this research paper

What this paper is about

Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (CV), ranged from 2.6% to 5.9% for RBC counts between 875 and 475 x 10(6)/L and from 4.2% to 6.5% for nucleated cell counts between 820 and 590 x 10(6)/L. The lower limits of detection, based on a CV of 20% or less, were 30 and 35 x 10(6)/L for RBCs and nucleated cells, respectively. There was very good agreement between automated iQ200 and manual body fluid cell counts based on slopes and r2 values. The iQ200 has satisfactory performance for enumerating RBCs and nucleated cells in most body fluids, with the exception of cerebrospinal fluid specimens that contain low cell numbers.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (CV), ranged from 2.6% to 5.9% for RBC counts between 875 and 475 x 10(6)/L and from 4.2% to 6.5% for nucleated cell counts between 820 and 590 x 10(6)/L. The lower limits of detection, based on a CV of 20% or less, were 30 and 35 x 10(6)/L for RBCs and nucleated cells, respectively. There was very good agreement between automated iQ200 and manual body fluid cell counts based on slopes and r2 values. The iQ200 has satisfactory performance for enumerating RBCs and nucleated cells in most body fluids, with the exception of cerebrospinal fluid specimens that contain low cell numbers.

Key concepts: Hemocytometer, Body fluid, Cell counting, Coefficient of variation, Biomedical engineering, Microscopy, Giemsa stain, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
A Multicenter Evaluation of the Iris iQ200 Automated Urine Microscopy Analyzer Body Fluids Module and Comparison With Hemacytometer Cell Counts — Research Paper | ScholarLens