2012•Research in Astronomy and AstrophysicsOpen access

The X-ray nature of the nucleus in Seyfert 2 galaxy NGC 7590

Xinwen Shu, Junxian Wang, Teng Liu, Wei Zheng

Open full text 2 citations

Abstract

We present the results of the Chandra high-resolution observation of the Seyfert 2 galaxy NGC 7590. This object was reported to show no X-ray absorption in the low-spatial resolution ASCA data. The XMM-Newton observations show that the X-ray emission of NGC 7590 is dominated by an off-nuclear ultra-luminous X-ray source (ULX) and extended emissions from the host galaxy, and the nucleus is rather weak, likely hosting a Compton-thick AGN. Our recent Chandra observation of NGC 7590 enables us to effectively remove the X-ray contamination from the ULX and the extended component. The nuclear source remains undetected at the flux level of ∼ 4 × 10 −15 erg cm −2 s −1 . Although not detected, the Chandra data give a 2–10 keV flux upper limit of ∼ 6.1 × 10 −15 erg cm −2 s −1 (at a 3σ level), a factor of three less than the XMM-Newton value, strongly supporting the Compton-thick nature of the nucleus. In addition, we detected five off-nuclear X-ray point sources within the galaxy's D 25 ellipse, all with 2 − 10 keV luminosity above 2 × 10 38 erg s −1 (assuming the distance of NGC 7590). In particular, the ULX previously identified by ROSAT data is resolved by Chandra into two distinct X-ray sources. Our analysis highlights the importance of high spatial resolution images in discovering and studying ULXs.

Open-access reader

About this research paper

What this paper is about

We present the results of the Chandra high-resolution observation of the Seyfert 2 galaxy NGC 7590. This object was reported to show no X-ray absorption in the low-spatial resolution ASCA data. The XMM-Newton observations show that the X-ray emission of NGC 7590 is dominated by an off-nuclear ultra-luminous X-ray source (ULX) and extended emissions from the host galaxy, and the nucleus is rather weak, likely hosting a Compton-thick AGN. Our recent Chandra observation of NGC 7590 enables us to effectively remove the X-ray contamination from the ULX and the extended component. The nuclear source remains undetected at the flux level of ∼ 4 × 10 −15 erg cm −2 s −1 . Although not detected, the Chandra data give a 2–10 keV flux upper limit of ∼ 6.1 × 10 −15 erg cm −2 s −1 (at a 3σ level), a factor of three less than the XMM-Newton value, strongly supporting the Compton-thick nature of the nucleus. In addition, we detected five off-nuclear X-ray point sources within the galaxy's D 25 ellipse, all with 2 − 10 keV luminosity above 2 × 10 38 erg s −1 (assuming the distance of NGC 7590). In particular, the ULX previously identified by ROSAT data is resolved by Chandra into two distinct X-ray sources. Our analysis highlights the importance of high spatial resolution images in discovering and studying ULXs.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present the results of the Chandra high-resolution observation of the Seyfert 2 galaxy NGC 7590. This object was reported to show no X-ray absorption in the low-spatial resolution ASCA data. The XMM-Newton observations show that the X-ray emission of NGC 7590 is dominated by an off-nuclear ultra-luminous X-ray source (ULX) and extended emissions from the host galaxy, and the nucleus is rather weak, likely hosting a Compton-thick AGN. Our recent Chandra observation of NGC 7590 enables us to effectively remove the X-ray contamination from the ULX and the extended component. The nuclear source remains undetected at the flux level of ∼ 4 × 10 −15 erg cm −2 s −1 . Although not detected, the Chandra data give a 2–10 keV flux upper limit of ∼ 6.1 × 10 −15 erg cm −2 s −1 (at a 3σ level), a factor of three less than the XMM-Newton value, strongly supporting the Compton-thick nature of the nucleus. In addition, we detected five off-nuclear X-ray point sources within the galaxy's D 25 ellipse, all with 2 − 10 keV luminosity above 2 × 10 38 erg s −1 (assuming the distance of NGC 7590). In particular, the ULX previously identified by ROSAT data is resolved by Chandra into two distinct X-ray sources. Our analysis highlights the importance of high spatial resolution images in discovering and studying ULXs.

Key concepts: Physics, ROSAT, Astrophysics, Galaxy, Luminosity, Flux (metallurgy), Astronomy, Active galactic nucleus

Related papers

Back to paper searchBrowse research topicsOriginal source
The X-ray nature of the nucleus in Seyfert 2 galaxy NGC 7590 — Research Paper | ScholarLens