Subcooled Pool Boiling Studies on Nano-Textured Surfaces
Vijaykumar Sathyamurthi, Debjyoti Banerjee
Abstract
Vijaykumar Sathyamurthi, Debjyoti Banerjee
Abstract
Heat transfer in subcooled pool boiling on nano-textured surfaces is reported in this study. Silicon wafers coated with Multiwalled Carbon Nanotubes (MWCNT) forests 9 microns (Type-A), and 25 microns (Type-B) in height and 8–15 nm in diameter with a randomized pitch of 16–30 nm, form the test surfaces. The test fluid is a fluoroinert (PF-5060, Manufacturer: 3M Co.) with a boiling point of 56°C. The test rig is of the constant heat flux type. Heat transfer enhancement of approximately 1.3 to 32% is observed in the nucleate boiling regime for Type-A at subcooling levels of 20°C. Type-B CNT shows an enhancement of about 13–30% in the nucleate boiling regime for 20°C subcooling. Digital images acquired during the tests show increased nucleation occurring on surfaces coated with MWCNT. Potential factors that could explain the observed heat transfer enhancement are: the enhanced surface area (nano-fin effect), disruption of the “microlayer” region in nucleate boiling, an increase in the size of cold-spots and the high thermal conductivity of MWCNT.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Heat transfer in subcooled pool boiling on nano-textured surfaces is reported in this study. Silicon wafers coated with Multiwalled Carbon Nanotubes (MWCNT) forests 9 microns (Type-A), and 25 microns (Type-B) in height and 8–15 nm in diameter with a randomized pitch of 16–30 nm, form the test surfaces. The test fluid is a fluoroinert (PF-5060, Manufacturer: 3M Co.) with a boiling point of 56°C. The test rig is of the constant heat flux type. Heat transfer enhancement of approximately 1.3 to 32% is observed in the nucleate boiling regime for Type-A at subcooling levels of 20°C. Type-B CNT shows an enhancement of about 13–30% in the nucleate boiling regime for 20°C subcooling. Digital images acquired during the tests show increased nucleation occurring on surfaces coated with MWCNT. Potential factors that could explain the observed heat transfer enhancement are: the enhanced surface area (nano-fin effect), disruption of the “microlayer” region in nucleate boiling, an increase in the size of cold-spots and the high thermal conductivity of MWCNT.
Key concepts: Subcooling, Nucleate boiling, Materials science, Boiling, Nucleation, Heat transfer, Wafer, Heat flux